Datasheet
Note 2: All devices are production tested at T
A
 = +25°C. Limits over temperature are guaranteed by design.
Note 3: When V
CC
 falls below the UVLO threshold, the outputs will deassert (OUT goes low, OUT goes high). When V
CC
 falls 
below 1.2V, the out cannot be determined.
Note 4: Guaranteed by design.
Note 5: During the initial power-up, V
CC
 must exceed 1.5V for at least 2ms before the output is guaranteed to be in the correct 
state.
(V
CC
 = 1.5V to 5.5V, T
A
 = -40°C to +125°C, unless otherwise specified. Typical values are at V
CC
 = 3.3V and T
A
 = +25°C, unless  
otherwise noted.) (Note 2)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
OUT/OUT
Output Low Voltage (Open-Drain 
or Push-Pull)
V
OL
V
CC
 ≥ 1.2V, I
SINK
 = 90µA,
MAX6895/MAX6897/MAX6899 only
0.3
V
V
CC
 ≥ 2.25V, I
SINK
 = 0.5mA 0.3
V
CC
 ≥ 4.5V, I
SINK
 = 1mA 0.4
Output High Voltage (Push-Pull) V
OH
V
CC
 ≥ 2.25V, I
SOURCE
 = 500µA
0.8 x 
V
CC
V
V
CC
 ≥ 4.5V, I
SOURCE
 = 800µA
0.8 x 
V
CC
Output Open-Drain Leakage 
Current
I
LKG
Output high impedance, V
OUT
 = 28V 1 µA
TIMING
IN to OUT/OUT Propagation 
Delay
t
DELAY
V
IN
 rising 
C
CDELAY
 = 0µF 40 µs
C
CDELAY
 = 0.047µF 190 ms
t
DL
V
IN
 falling 16 µs
Startup Delay (Note 5) 2 ms
ENABLE/ENABLE Minimum 
Input Pulse Width
t
PW
1 µs
ENABLE/ENABLE Glitch 
Rejection
100 ns
ENABLE/ENABLE to OUT/OUT 
Delay
t
OFF
From device enabled to device disabled 150 ns
ENABLE/ENABLE to OUT/OUT 
Delay
t
PROPP
From device disabled to device enabled 
(P version)
150 ns
t
PROPA
From device disabled 
to device enabled 
(A version)
C
CDELAY
 = 0µF 20 µs
C
CDELAY
 = 0.047µF 190 ms
www.maximintegrated.com
Maxim Integrated 
│
  3
MAX6895–MAX6899 Ultra-Small, Adjustable Sequencing/ 
Supervisory Circuits
Electrical Characteristics (continued)