Datasheet

MAX6754–MAX6764
Low-Power, Single/Dual-Voltage Window
Detectors
_______________________________________________________________________________________ 7
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 1.0V to 6.0V, V
CC2
= 0 to 6.0V (MAX6760–MAX6762), T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at T
A
=
+25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Any V
CC
1.98V, I
SINK
= 1.4mA,
output asserted
0.3
Any V
CC
2.75V, I
SINK
= 2.0mA,
output asserted
0.3
Any V
CC
3.63V, I
SINK
= 3.0mA,
output asserted
0.3
OV Output Low
(Open-Drain or
Push-Pull)
V
OL
Any V
CC
5.5V, I
SINK
= 4.0mA,
output asserted
0.3
V
Any V
CC
1.0V, I
SOURCE
= 50µA,
output deasserted
0.8 x
V
CC
Any V
CC
1.2V, I
SOURCE
= 100µA,
output deasserted
0.8 x
V
CC
Any V
CC
1.98V, I
SOURCE
= 1.4mA,
output deasserted
0.8 x
V
CC
Any V
CC
2.75V, I
SOURCE
= 2.0mA,
output deasserted
0.8 x
V
CC
Any V
CC
3.63V, I
SOURCE
= 3.0mA,
output deasserted
0.8 x
V
CC
OV Output High
(Push-Pull)
V
OH
Any V
CC
5.5V, I
SOURCE
= 4.5mA,
output deasserted
0.8 x
V
CC
V
RESET, UV, OV Output Open-
Drain Leakage Current
I
LKG
Output not asserted 1 µA
Note 1: Devices are production tested at +25°C. Overtemperature limits are guaranteed by design.
Note 2: Voltage monitoring requires that V
CC
must be greater than or equal to 1.4V, but outputs remain asserted in the correct
state for V
CC
down to 1.0V.
Note 3: Guaranteed by design.
Note 4: For D0 window detector options and OV outputs, startup delay time is the time required for the internal reference/circuitry
to reach specified accuracy after the monitor is powered up from GND.
Note 5: The input bias voltage is based off of V
CC
. The minimum value is given by the equation (0.1 x V
CC
+ 0.51)V and the maxi-
mum value is given by (0.9 x V
CC
- 0.51)V.