MAX6699
5-Channel Precision Temperature Monitor
10 ______________________________________________________________________________________
REGISTER
ADDRESS
(HEX)
POR STATE
(HEX)
READ/
WRITE
DESCRIPTION
Local 07 00 R Read local temperature register
Remote 1 01 00 R Read channel 1 remote temperature register
Remote 2 02 00 R Read channel 2 remote temperature register
Remote 3 03 00 R Read channel 3 remote temperature register
Remote 4 04 00 R Read channel 4 remote temperature register
Reserved 05 00 R
Reserved 06 00 R
Configuration 1 41 00 R/W Read/write configuration register 1
Configuration 2 42 00 R/W Read/write configuration register 2
Configuration 3 43 00 R/W Read/write configuration register 3
Status1 44 00 R Read status register 1
Status2 45 00 R Read status register 2
Status3 46 00 R Read status register 3
Local ALERT High Limit 17 5A R/W
Read/write local alert high-temperature threshold limit register
Remote 1 ALERT High Limit
11 6E R/W
Read/write channel 1 remote-diode alert high-temperature
threshold limit register
Remote 2 ALERT High Limit
12 7F R/W
Read/write channel 2 remote-diode alert high-temperature
threshold limit register
Remote 3 ALERT High Limit
13 64 R/W
Read/write channel 3 remote-diode alert high-temperature
threshold limit register
Remote 4 ALERT High Limit
14 64 R/W
Read/write channel 4 remote-diode alert high-temperature
threshold limit register
Reserved 15 64 R/W
Reserved 16 64 R/W
Remote 1 OVERT High Limit
21 6E R/W
Read/write channel 1 remote-diode overtemperature threshold
limit register
Remote 4 OVERT High Limit
24 7F R/W
Read/write channel 4 remote-diode overtemperature threshold
limit register
Reserved 25 5A R/W
Reserved 26 5A R/W
Remote 1 Extended
Temperature
09 00 R Read channel 1 remote-diode extended temperature register
Manufacturer ID 0A 4D R Read manufacturer ID
Table 3. Command Byte Register Bit Assignment