Datasheet

MAX6698
7-Channel Precision Remote-Diode, Thermistor,
and Local Temperature Monitor
______________________________________________________________________________________ 15
BIT NAME
POR
STATE
FUNCTION
7(MSB) Reserved 0 —
6 Reserved 0 —
5 Thermistor 3 OVERT 0
Thermistor 3 Overtemperature Status Bit. This bit is set to logic 1 when the
thermistor 3 voltage exceeds the threshold limit in the thermistor 3 OVERT
high-limit register.
4 Thermistor 2 OVERT 0
Thermistor 2 Overtemperature Status Bit. This bit is set to logic 1 when the
thermistor 2 voltage exceeds the threshold limit in the thermistor 2 OVERT
high-limit register.
3 Thermistor 1 OVERT 0
Thermistor 1 Overtemperature Status Bit. This bit is set to logic 1 when the
thermistor 1 voltage exceeds the threshold limit in the thermistor 1 OVERT
high-limit register.
2 Reserved 0 —
1 Reserved 0 —
0 Remote 1 OVERT 0
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
Table 9. Status 2 Register
BIT NAME
POR
STATE
FUNCTION
7(MSB) Reserved 0 —
6 Reserved 0 —
5 Reserved 0 —
4 Reserved 0 —
3 Diode fault 3 0
Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3
are open circuit or when DXP3 is connected to V
CC
.
2 Diode fault 2 0
Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2
are open circuit or when DXP2 is connected to V
CC
.
1 Diode fault 1 0
Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1
are open circuit or when DXP1 is connected to V
CC
.
0 Reserved 0 —
Table 10. Status 3 Register