Datasheet

MAX6697
7-Channel Precision Temperature Monitor
______________________________________________________________________________________ 15
BIT NAME
POR
STATE
FUNCTION
7(MSB) Reserved 0
6 Reserved 0
5 Remote 6 OVERT 0
Channel 6 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 6 remote-diode temperature exceeds the temperature
threshold limit in the remote 6 OVERT high-limit register.
4 Remote 5 OVERT 0
Channel 5 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 5 remote-diode temperature exceeds the temperature
threshold limit in the remote 5 OVERT high-limit register.
3 Remote 4 OVERT 0
Channel 4 Remote Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
2 Reserved 0
1 Reserved 0
0 Remote 1 OVERT 0
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
Table 8. Status 2 Register
BIT NAME
POR
STATE
FUNCTION
7(MSB) Reserved 0
6 Diode fault 6 0
Channel 6 Remote-Diode Fault Bit. This bit is set to 1 when DXP6 and DXN6
are open circuit or when DXP6 is connected to V
CC
.
5 Diode fault 5 0
Channel 5 Remote-Diode Fault Bit. This bit is set to 1 when DXP5 and DXN5
are open circuit or when DXP5 is connected to V
CC
.
4 Diode fault 4 0
Channel 4 Remote-Diode Fault Bit. This bit is set to 1 when DXP4 and DXN4
are open circuit or when DXP4 is connected to V
CC
.
3 Diode fault 3 0
Channel 3 Remote-Diode Fault Bit. This bit is set to 1 when DXP3 and DXN3
are open circuit or when DXP3 is connected to V
CC
.
2 Diode fault 2 0
Channel 2 Remote-Diode Fault Bit. This bit is set to 1 when DXP2 and DXN2
are open circuit or when DXP2 is connected to V
CC
.
1 Diode fault 1 0
Channel 1 Remote-Diode Fault Bit. This bit is set to 1 when DXP1 and DXN1
are open circuit or when DXP1 is connected to V
CC
.
0 Reserved 0
Table 9. Status 3 Register