Datasheet

MAX6694
5-Channel Precision Temperature Monitor
with Beta Compensation
_______________________________________________________________________________________ 9
TEMP (°C) DIGITAL OUTPUT
> +127 0111 1111
+127 0111 1111
+126 0111 1110
+25 0001 1001
0 0000 0000
< 0 0000 0000
Diode fault (short or open) 1111 1111
Table 1. Main Temperature Register
(High Byte) Data Format
TEMP (°C) DIGITAL OUTPUT
0 000X XXXX
+0.125 001X XXXX
+0.250 010X XXXX
+0.375 011X XXXX
+0.500 100X XXXX
+0.625 101X XXXX
+0.750 110X XXXX
+0.875 111X XXXX
Table 2. Extended Resolution Temperature
Register (Low Byte) Data Format
SMBCLK
A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.
AB CD
E
FG
HIJ
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
SU:STO
t
BUF
LMK
E = SLAVE PULLS SMBDATA LINE LOW.
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKE D INTO SLAVE.
H = LSB OF DATA CLOCKED INTO SLAVE.
I = MASTER PULLS DATA LINE LOW.
J = ACKNOWLEDGE CLOCKED INTO SLAVE.
K = ACKNOWLEDGE CLOCK PULSE.
L = STOP CONDITION.
M = NEW START CONDITION.
Figure 3. SMBus Write-Timing Diagram
SMBCLK
AB CD
E
FG H
I
J
K
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:STO
t
BUF
A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.
E = SLAVE PULLS SMBDATA LINE LOW.
L
M
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKED INTO MASTER.
H = LSB OF DATA CLOCKED INTO MASTER.
I = MASTER PULLS DATA LINE LOW.
J = ACKNOWLEDGE CLOCKED INTO SLAVE.
K = ACKNOWLEDGE CLOCK PULSE.
L = STOP CONDITION.
M = NEW START CONDITION.
Figure 4. SMBus Read-Timing Diagram