Datasheet
(All voltages referenced to GND.)
V
CC
..........................................................................-0.3V to +6V
SDO, SCK, DXP, CS ................................ -0.3V to (V
CC
+ 0.3V)
DXN ......................................................................-0.3V to +0.8V
SDO Pin Current Range ..................................... -1mA to +50mA
Current Into All Other Pins .................................................10mA
ESD Protection (Human Body Model).............................±2000V
Continuous Power Dissipation (T
A
= +70°C)
SOT23 (derate 9.7mW/°C above +70°C) ....................777mW
TDFN (derate 18.5mW/°C above +70°C) ............... 1481.5mW
Operating Temperature Range ......................... -55°C to +125°C
Junction Temperature ...................................................... +150°C
Storage Temperature Range ............................ -65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) ....................................... +260°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
TEMPERATURE
Accuracy (Note 1)
0°C ≤ T
RJ
≤ +125°C, T
A
= +30°C,
V
CC
= +3.3V
-1.0 ±0.5 ±1
°C
-55°C ≤ T
RJ
≤ +100°C, 0°C ≤ T
A
≤ +70°C,
V
CC
= +3.3V
-2.4 +2.4
-55°C ≤ T
RJ
≤ +145°C, 0°C ≤ T
A
≤ +70°C,
V
CC
= +3.3V
-4.5 +4.5
-55°C ≤ T
RJ
≤ +125°C, -55°C ≤ T
A
≤
+125°C,V
CC
= +3.3V
-5.5 +5.5
Power-Supply Sensitivity 0.25 0.7 °C/V
Resolution 0.0625 °C
Time Between Conversion
Starts
t
SAMPLE
MAX6627 0.5
s
MAX6628 8
Conversion Time t
CONV
180 250 320 ms
POWER SUPPLY
Supply Voltage Range V
CC
3.0 5.5 V
Supply Current, SCK Idle
I
SDO
Shutdown, V
CC
= +0.8V 5
µAI
IDLE
ADC idle, CS = low 20
I
CONV
ADC converting 360 600
Average Operating Current I
CC
MAX6627 200 400
µA
MAX6628 30 50
Power-On Reset (POR)
Threshold
V
CC
, falling edge 1.6 V
Current Sourcing for Diode
High level 80 100 120
µA
Low level 8 10 12
MAX6627/MAX6628 Remote ±1ºC Accurate Digital Temperature
Sensors with SPI-Compatible Serial Interface
www.maximintegrated.com
Maxim Integrated
│
2
(3.0V ≤ V
CC
≤ 5.5V, -55°C ≤ T
A
≤ +125°C, unless otherwise noted. Typical values are at T
A
= +25°C, V
CC
= +3.3V, unless otherwise
noted.)
Electrical Characteristics
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Absolute Maximum Ratings