Datasheet
7Maxim Integrated
Evaluates: MAX6581
MAX6581 Evaluation Kit
Table 4. OVERT Mask Register Checkboxes
Table 5. ALERT High Status Register
*Power-on-reset (POR) state.
BIT NAME STATE DESCRIPTION
7
Mask OVERT 7
Checked
Disables the remote-diode 7 OVERT interrupt.
Unchecked*
Enables the remote-diode 7 OVERT interrupt.
6
Mask Local OVERT
Checked
Disables the local OVERT interrupt.
Unchecked*
Enables the local OVERT interrupt.
5
Mask OVERT 6
Checked
Disables the remote-diode 6 OVERT interrupt.
Unchecked*
Enables the remote-diode 6 OVERT interrupt.
4
Mask OVERT 5
Checked
Disables the remote-diode 5 OVERT interrupt.
Unchecked*
Enables the remote-diode 5 OVERT interrupt.
3
Mask OVERT 4
Checked
Disables the remote-diode 4 OVERT interrupt.
Unchecked*
Enables the remote-diode 4 OVERT interrupt.
2
Mask OVERT 3
Checked
Disables the remote-diode 3 OVERT interrupt.
Unchecked*
Enables the remote-diode 3 OVERT interrupt.
1
Mask OVERT 2
Checked
Disables the remote-diode 2 OVERT interrupt.
Unchecked*
Enables the remote-diode 2 OVERT interrupt.
0
Mask OVERT 1
Checked
Disables the remote-diode 1 OVERT interrupt.
Unchecked*
Enables the remote-diode 1 OVERT interrupt.
BIT NAME FUNCTION
7
Remote ALERT 7
The channel 7 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 7 ALERT High Limit register.
6
Local ALERT
The local temperature exceeds the temperature threshold limit in the local ALERT High
Limit register.
5
Remote ALERT 6
The channel 6 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 6 ALERT High Limit register.
4
Remote ALERT 5
The channel 5 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 5 ALERT High Limit register.
3
Remote ALERT 4
The channel 4 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 4 ALERT High Limit register.
2
Remote ALERT 3
The channel 3 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 3 ALERT High Limit register.
1
Remote ALERT 2
The channel 2 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 2 ALERT High Limit register.
0
Remote ALERT 1
The channel 1 remote-diode temperature exceeds the programmed temperature threshold
limit in the remote 1 ALERT High Limit register.