Datasheet

MAX6457–MAX6460
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
2
Maxim Integrated
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
CC
= 4V to 28V, T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
V
CC
, OUT, OUTA, OUTB, CLEAR to GND ..........-0.3V to +30.0V
IN+, IN- to GND..........................................-0.3V to (V
CC
+ 0.3V)
REF to GND..............-0.3V to the lower of +6V and (V
CC
+ 0.3V)
Input Currents (V
CC
, IN+, IN-) ............................................20mA
Sink Current (OUT, OUTA, OUTB) ......................................20mA
Continuous Power Dissipation (T
A
= +70°C)
5-Pin SOT23 (derate 7.1 mW/°C above +70°C)............571mW
6-Pin SOT23 (derate 8.7 mW/°C above +70°C)............696mW
Junction Temperature......................................................+150°C
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow)
Lead(Pb)-free................................................................+260°C
Containing lead (Pb) .....................................................+240°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Operating Voltage Range V
CC
(Note 2) 4 28 V
V
CC
= 5V, no load 2 5
V
CC
= 12V, no load 3.5 7.5Supply Current I
CC
V
CC
= 24V, no load 6.5 12.5
µA
T
A
= -40°C to +85°C, V
CC
4V 1.195 1.228 1.255
V
TH+
V
IN
rising
T
A
= +85°C to +125°C, V
CC
4V 1.170 1.255
T
A
= -40°C to +85°C 1.180 1.255
MAX645_U_D_A
T
A
= +85°C to +125°C 1.155 1.255
T
A
= -40°C to +85°C 1.133 1.194
MAX645_U_D_B
T
A
= +85°C to +125°C 1.111 1.194
T
A
= -40°C to +85°C 1.093 1.151
Threshold Voltage
V
TH-
V
IN
falling
MAX645_U_D_C
T
A
= +85°C to +125°C 1.071 1.151
V
MAX64_ _U_D_A 0.5
MAX64_ _U_D_B 5Threshold Voltage Hysteresis
MAX64_ _U_D_C 8.3
%V
TH+
IN Operating Voltage Range V
IN
(Note 2) 0 V
CC
V
IN Leakage Current I
IN
V
IN
= 1.25V, V
CC
= +28V -55 +55 nA
MAX645_UKD0_
MAX6459UT_
MAX6460UT
50 µs
OUT Timeout Period t
TP
MAX6457 and MAX6458 only,
D3 option
90 150 210 ms
Startup Time
V
CC
rising from GND to V
CC
4V in less than
1µs (Note 3)
2ms
V
IL
0.4
CLEAR Input Logic Voltage
(MAX6457)
V
IH
2
V