Datasheet
MAX6457–MAX6460
High-Voltage, Low-Current Voltage Monitors in
SOT Packages
12
Maxim Integrated
PART SUFFIX TIMEOUT OPTION HYSTERESIS OPTION (%)
0A 50µs 0.5
0B 50µs 5
0C 50µs 8.3
3A 150ms 0.5
3B 150ms 5
MAX6457UKD_ _ -T
MAX6458UKD_ _ -T
3C 150ms 8.3
A 50µs 0.5
B 50µs 5MAX6459UT_ -T
C 50µs 8.3
MAX6460UT-T N/A 50µs 0.5
PART
PIN
COUNT
LATCHED
OUTPUT
NUMBER OF
OUTPUTS
HYSTERESIS
(%V
TH+
)
TIMEOUT
PERIOD
TOP MARK COMPARATORS
MAX6457UKD0A-T 5 ✓ 1 0.5 50µs AEAA 1
MAX6457UKD3A-T 5 ✓ 1 0.5 150ms AANN 1
MAX6457UKD0B-T 5 ✓ 1 5 50µs AANL 1
MAX6457UKD3B-T 5 ✓ 1 5 150ms AANO 1
MAX6457UKD0C-T 5 ✓ 1 8.3 50µs AANM 1
MAX6457UKD3C-T 5 ✓ 1 8.3 150ms ADZZ 1
MAX6458UKD0A-T 5 — 1 0.5 50µs AANP 2
MAX6458UKD3A-T 5 — 1 0.5 150ms AANS 2
MAX6458UKD0B-T 5 — 1 5 50µs AANQ 2
MAX6458UKD3B-T 5 — 1 5 150ms AEAB 2
MAX6458UKD0C-T 5 — 1 8.3 50µs AANR 2
MAX6458UKD3C-T 5 — 1 8.3 150ms AANT 2
MAX6459UTA-T 6 — 2 0.5 50µs ABML 2
MAX6459UTB-T 6 — 2 5 50µs ABEJ 2
MAX6459UTC-T 6 — 2 8.3 50µs ABMM 2
MAX6460UT-T 6 — 1 0.5 50µs ABEG 1
Selector Guide
Table 1. Factory-Trimmed Internal Hysteresis and Timeout Period Options