ELECTRICAL CHARACTERISTICSMAX6133_30 (V
OUT
= 3.0000V)
(V
IN
= 5V, C
LOAD
= 0.1µF, I
OUT
= 0, T
A
= T
MIN
to T
MAX
. Typical values are at T
A
= +25°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
A grade SO 2.9988 3.0000 3.0012
B grade SO 2.9976 3.0000 3.0024
Output Voltage V
OUT
T
A
= +25°C
µMAX 2.9982 3.0000 3.0018
V
A grade SO -0.04 +0.04
B grade SO -0.08 +0.08
Output Voltage
Accuracy
T
A
= +25°C
µMAX -0.06 +0.06
%
T
A
= -40°C to +85°C13
A grade SO
T
A
= -40°C to +125°C47
T
A
= -40°C to +85°C35
B grade SO
T
A
= -40°C to +125°C510
T
A
= -40°C to +85°C15
Output Voltage
Temperature
Coefficient (Note 1)
TCV
OUT
µMAX
T
A
= -40°C to +125°C27
ppm/°C
Input Voltage Range V
IN
Inferred from line regulation 3.2 12.6 V
Line Regulation V
OUT
/V
IN
3.2V V
IN
12.6V 2 30 µV/V
Load Regulation V
OUT
/I
OUT
-100µA I
OUT
15mA 0.003 0.06 mV/mA
V
OUT
= 0.1%, I
OUT
= 1mA 0.01 0.2
Dropout Voltage
(Note 2)
V
DO
V
OUT
= 0.1%, I
OUT
= 10mA 0.2 0.4
V
T
A
= +25°C4060
Quiescent Supply
Current
I
IN
T
A
= -40°C to +125°C85
µA
Short to GND: V
OUT
= 0V 90
Output Short-Circuit
Current
I
SC
Short to V
IN
: V
OUT
= V
IN
-2
mA
0.1Hz f 10Hz 24 µV
P-P
Output Voltage Noise e
n
10Hz f 1kHz 15 µV
RMS
Turn-On Settling Time t
ON
V
OUT
settles to ±0.01% of final value 600 µs
Thermal Hysteresis
(Note 3)
120 ppm
SO 40
Long-Term Stability t = 1000 hours
µMAX 145
ppm