Datasheet

MAX4947/MAX4948
Hex SPDT Data Switch
4 _______________________________________________________________________________________
Typical Operating Characteristics
(V
CC
= 3V, T
A
= +25°C, unless otherwise noted.)
ON-RESISTANCE vs. V
COM
V
COM
(V)
ON-RESISTANCE (Ω)
MAX4947/48 toc01
012345
0
5
10
15
20
25
30
35
40
V
CC
= 1.8V
V
CC
= 2.0V
V
CC
= 2.3V
V
CC
= 2.7V
V
CC
= 3.0V
V
CC
= 5.0V
ON-RESISTANCE
vs. V
COM
TEMPERATURE
V
COM
(V)
R
ON
(Ω)
MAX4947/48 toc02
0 0.5 1.0 1.5 2.0 2.5 3.0
0
1
2
3
4
5
6
7
T
A
= +85°C
T
A
= +25°C
T
A
= -40°C
V
CC
= 3V
ON-RESISTANCE
vs. V
COM
AND TEMPERATURE
V
COM
(V)
R
ON
(Ω)
MAX4947/48 toc03
012345
0
1
2
3
4
5
T
A
= +85°C
T
A
= +25°C
T
A
= -40°C
V
CC
= 5V
NO/NC OFF-LEAKAGE CURRENT
vs. TEMPERATURE
MAX4947/48 toc04
TEMPERATURE (°C)
NO/NC OFF-LEAKAGE CURRENT (nA)
603510-15
0.001
0.01
0.1
1
10
0.0001
-40 85
V
CC
= 3V
V
CC
= 3V/5V
V
CC
= 5V
COM ON-LEAKAGE CURRENT
vs. TEMPERATURE
MAX4947/48 toc05
TEMPERATURE (°C)
COM ON-LEAKAGE CURRENT (nA)
603510-15
0.001
0.01
0.1
1
10
0.0001
-40 85
V
CC
= 3V
V
CC
= 3V/5V
V
CC
= 5V
COM OFF-LEAKAGE CURRENT
vs. TEMPERATURE (MAX4748)
MAX4947/48 toc06
TEMPERATURE (°C)
COM OFF-LEAKAGE CURRENT (nA)
603510-15
0.001
0.01
0.1
1
10
0.0001
-40 85
V
CC
= 3V
V
CC
= 3V/5V
V
CC
= 5V
Note 2: The algebraic convention is used. The most negative value is shown in the minimum column.
Note 3: UCSP parts are 100% tested at T
A
= +25°C. Limits across the full temperature range are guaranteed by correlation and
design. TQFN parts are guaranteed by correlation and design at - 40°C.
Note 4: R
ON
and ΔR
ON
matching specifications are guaranteed by design.
Note 5: ΔR
ON
= R
ON(MAX)
- R
ON(MIN)
.
Note 6: Flatness is defined as the difference between the maximum and minimum value of on-resistance as measured over the
specified analog signal ranges.
Note 7: Guaranteed by design, not production tested.
Note 8: Off-Isolation = 20log
10
[V
COM_
/ (V
NO_
or V
NC_
)], V
COM_
= output, V
NO_
or V
NC_
= input to off switch.
Note 9: Between any two switches.
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +2.7V to +5.5V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at V
CC
= +3V, T
A