Datasheet

MAX4785–MAX4788
50mA/100mA Current-Limit Switches
_______________________________________________________________________________________ 3
Typical Operating Characteristics
(V
IN
= 3.3V, T
A
= +25°C, unless otherwise noted.)
Note 1: All parts are 100% tested at +25°C. Limits across the full temperature range are guaranteed by design and correlation.
Note 2: Latch-off current does not include the current flowing into FLAG.
Note 3: The on-time is defined as the time taken for the current through the switch to go from 0mA to full load. The off-time is defined
as the time taken for the current through the switch to go from full load to 0mA.
Note 4: Retry time is typically 7x the blanking time.
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= 2.3V to 5.5V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at V
IN
= 3.3V, T
A
= +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
Blanking Time t
BLANK
Overcurrent fault, Figures 2, 3 14 60 ms
Short-Circuit Current-Limit
Response Time
V
ON
= V
IN
= 3.3V, short circuit applied to
OUT
s
Retry Time (Note 4) t
RETRY
MAX4786/MAX4788: overcurrent fault,
Figure 2
98 420 ms