Datasheet
MAX4741/MAX4742/MAX4743
0.8
Ω
, Low-Voltage, Single-Supply Dual SPST
Analog Switches
_______________________________________________________________________________________ 5
ELECTRICAL CHARACTERISTICS—Single +1.8V Supply (continued)
(V+ = +1.8V, V
IH
= +1.0V, V
IL
= 0.4V, T
A
= T
MIN
to T
MAX
, unless otherwise specified. Typical values are at T
A
= +25°C.) (Notes 2, 3)
PARAMETER
SYMBOL
CONDITIONS T
A
MIN
TYP
MAX
UNITS
LOGIC INPUT
Input Logic High V
IH
1V
Input Logic Low V
IL
0.4 V
Input Leakage Current I
IN
V
IN
_ = 0 or V+ -1 1 µA
Note 2: The algebraic convention, where the most negative value is a minimum and the most positive value is a maximum, is
used in this data sheet.
Note 3: µDFN and SOT23 packaged parts are 100% tested at +25°C. Limits across the full temperature range are guaranteed by
design and correlation. µMAX packaged parts -40°C specifications are guaranteed by design.
Note 4: ∆R
ON
= R
ON(MAX)
- R
ON(MIN)
.
Note 5: Flatness is defined as the difference between the maximum and the minimum value of on-resistance as measured over the
specified analog signal ranges.
Note 6: Guaranteed by design.
Note 7: Off-Isolation = 20log
10
(V
COM
_/V
NO
_), V
COM
_ = output, V
NO
_ = input to off switch.
Note 8: Between two switches.
Typical Operating Characteristics
(T
A
= +25°C, unless otherwise noted.)
0
0.4
0.2
0.8
0.6
1.2
1.4
1.0
0 0.8 1.20.4 1.6 2.0 2.4 2.8 3.2 3.6
ON-RESISTANCE vs. V
COM
MAX4741 toc01
V
COM
(V)
R
ON
(Ω)
V+ = +1.8V
V+ = +2.5V
V+ = +2.7V
V+ = +3.0V
V+ = +3.3V
V+ = +2.0V
V+ = +3.6V
I
COM
= 100mA
0
0.2
0.1
0.4
0.3
0.6
0.5
0.7
0 0.6 0.90.3 1.2 1.5 1.8 2.1 2.4 2.7
ON-RESISTANCE vs. V
COM
AND TEMPERATURE
MAX4741 toc02
V
COM
(V)
R
ON
(Ω)
T
A
= +85°C
T
A
= +25°C
T
A
= -40°C
V+ = +2.7V
I
COM
= 100mA
8
16
12
24
20
28
32
40
36
44
1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6
TURN-ON/OFF TIME
vs. SUPPLY VOLTAGE
MAX4741 toc03
V+ (V)
t
ON
/t
OFF
(ns)
t
ON
t
OFF