Datasheet
MAX4715/MAX4716
0.4Ω, Low-Voltage, Single-Supply
SPST Analog Switches in SC70
_______________________________________________________________________________________ 7
Test Circuits/Timing Diagrams (continued)
MEASUREMENTS ARE STANDARDIZED AGAINST SHORTS AT IC TERMINALS.
OFF-ISOLATION IS MEASURED BETWEEN COM_ AND “OFF” NO_ OR NC_ TERMINAL ON EACH SWITCH.
ON-LOSS IS MEASURED BETWEEN COM_ AND “ON” NO_ OR NC_TERMINAL ON EACH SWITCH.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED.
+5V
V
OUT
V+
IN
NO
COM
50Ω USE
ONLY FOR
ISOLATION
V
IN
MAX4715
MAX4716
OFF-ISOLATION = 20log
V
OUT
V
IN
ON-LOSS = 20log
V
OUT
V
IN
NETWORK
ANALYZER
50Ω
50Ω 50Ω
50Ω
MEAS REF
10nF
0V OR V+
GND
Figure 3. On-Loss and Off-Isolation
CAPACITANCE
METER
NC or
NO
COM
GND
IN
V
INL
OR
V
INH
10nF
V+
f = 1MHz
V+
MAX4715
MAX4716
Figure 4. Channel Off/On-Capacitance
TRANSISTOR COUNT: 135
PROCESS: CMOS
Chip Information