Datasheet
MAX4711/MAX4712/MAX4713
Fault-Protected, Low-Voltage,
Quad SPST Analog Switches
______________________________________________________________________________________ 13
50%
t
ON
V+
0
V
OUT
V
IN_
0
90%
90%
t
OFF
V
IN_
V+
V
OUT
GND
V+
IN_
NO_ OR NC_
COM_
V
NO_
OR V
NC_
MAX4711
MAX4712
MAX4713
R
L
50Ω
C
L
V-
V-
V- IS CONNECTED TO GND (0) FOR SINGLE-SUPPLY OPERATION.
50%
V+
0
V
OUT
V
IN_
0
80%
t
OPEN
V+
V
OUT
V
IN_
GND V-
V-
R
L
V+
IN_
IN_
NO_
NC_
COM_
COM_
V
NO_
OR V
NC_
MAX4713
50Ω
C
L
V- IS CONNECTED TO GND (0) FOR SINGLE-SUPPLY OPERATION.
t
R
< 5ns
t
F
< 5ns
0
V+
V
IN_
∆ V
OUT
IS THE MEASURED VOLTAGE DUE TO CHARGE-
TRANSFER ERROR Q WHEN THE CHANNEL TURNS OFF.
∆ V
OUT
V- IS CONNECTED TO GND (0) FOR SINGLE-SUPPLY OPERATION. Q = ∆ V
OUT
x C
L
V
OUT
V+
V
OUT
V
IN_
GND
V+
V-
V-
IN_
NO_ OR NC_
COM_
MAX4711
MAX4712
MAX4713
50Ω
C
L
1000pF
Test Circuits/Timing Diagrams
Figure 2. Switch Turn-On/Turn-Off Times
Figure 4. Charge Injection
Figure 3. MAX4713 Break-Before-Make Interval