Datasheet
0
6
4
2
8
10
12
14
16
18
20
021345
ON-RESISTANCE vs. COM VOLTAGE
MAX4594–97 toc 01
COM VOLTAGE (V)
R
ON
(Ω)
V+ = 3V
V+ = 2V
V+ = 5V
0
2
1
4
3
6
5
7
023145
ON-RESISTANCE vs. COM VOLTAGE
(V+ = 5V)
MAX4594–97 toc 02
COM VOLTAGE (V)
R
ON
(Ω)
T
A
= +85°C
T
A
=
+25°C
T
A
= 0°C
T
A
= -40°C
0
3
2
1
5
4
9
8
7
6
10
0 0.5 1.0 1.5 2.0 2.5 3.0
ON-RESISTANCE vs. COM VOLTAGE
(V+ = 3V)
MAX4594–97 toc 03
COM VOLTAGE (V)
R
ON
(Ω)
T
A
= +85°C
T
A
=
+25°C
T
A
= 0°C
T
A
= -40°C
1
0.001
-40 -25 5 35 50 65 80
ON/OFF-LEAKAGE CURRENT vs.
TEMPERATURE
0.01
0.1
MAX4594-97 toc04
TEMPERATURE (°C)
ON/OFF-LEAKAGE CURRENT (nA)
-10 20
V+ = +5V
I
COM(ON)
NO, NC (OFF)
-3
-1
-2
1
0
3
2
4
0 2.01.0 3.0 4.0 5.0
CHARGE INJECTION
vs. COM VOLTAGE
MAX4594–97 toc 05
COM VOLTAGE (V)
CHARGE INJECTION (pC)
V+ = 5V
V+ = 3V
0.0001
0.001
0.1
0.01
1
10
-40 10-15 35 60 85
SUPPLY CURRENT vs. TEMPERATURE
MAX4594–97 toc 06
TEMPERATURE (°C)
SUPPLY CURRENT (nA)
V+ = +5V
V+ = +3V
Typical Operating Characteristics
(V+ = +5V, T
A
= +25°C, unless otherwise noted.)
MAX4594–MAX4597
Low-Voltage, Single-Supply,
10Ω SPST CMOS Analog Switches
4 _______________________________________________________________________________________
Note 2: Parameters are 100% tested at +25°C only, and guaranteed by correlation at the full-rated temperature.
Note 3: Algebraic convention is used in this data sheet; the most negative value is shown in the minimum column.
Note 4: Flatness is defined as the difference between the maximum and minimum values of on-resistance as measured over the
specified analog signal ranges.
Note 5: Guaranteed by design.
Note 6: Off-Isolation = 20log
10
(V
COM
/ V
NO
), V
COM
= output, V
NO
= input to off switch.
ELECTRICAL CHARACTERISTICS—+3V Supply (continued)
(V+ = +2.7V to +3.6V, V
IH
= +2.0V, V
IL
= +0.8V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V+ = +3.0V,
T
A
= +25°C.) (Notes 2, 3)
V+ = 3.6V, V
IN
= 0 or V+
µA
I+ -1 1T
A
= T
MIN
to T
MAX
V+ Supply Current
CONDITIONS
UNITS
MIN TYP MAXSYMBOL
PARAMETER
POWER SUPPLY