Datasheet
V-
NO_, NC_
COM_
V-
GND
EN
ADDRESS
SELECT
MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS. OFF ISOLATION IS MEASURED BETWEEN COM_ AND "OFF" NO_ OR NC_ TERMINALS.
ON LOSS IS MEASURED BETWEEN COM_ AND "ON" NO_ OR NC_ TERMINALS. CROSSTALK IS MEASURED BETWEEN COM_ TERMINALS WITH ALL SWITCHES ON.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED. V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION.
V
OUT
V
IN
MEAS. REF
50Ω
50Ω 50Ω
50Ω
IN_
VL
10nF
VL
10nF
VL
MAX4554
MAX4555
MAX4556
NETWORK
ANALYZER
V+
10nF
V+
OFF ISOLATION = 20 log
VOUT
VIN
ON LOSS = 20 log
VOUT
VIN
CROSSTALK = 20 log
VOUT
VIN
Figure 15. Frequency Response, Off-Isolation, and Crosstalk
MAX4554/MAX4555/MAX4556
Force-Sense Switches
26 ______________________________________________________________________________________
V-
COM_
NO_ OR NC_
∆V
OUT
V
OUT
V
IN
VL
0V
V-
GND
∆V
OUT
IS THE MEASURED VOLTAGE DUE TO CHARGE TRANSFER
ERROR Q WHEN THE CHANNEL TURNS OFF.
V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION.
IN_
V
IN_
C
L
1000pF
50Ω
EN
VL
VL
V+
V+
V
OUT
MAX4554
MAX4555
MAX4556
Q = ∆V
OUT
x C
L
_________________________________Test Circuits/Timing Diagrams (continued)
Figure 13. Charge Injection
V-
COM_
NC_
NO_
V-
GND
ADDRESS
SELECT
IN_
VL
EN
V+
V+
VL
VL
MAX4554
MAX4555
MAX4556
1MHz
CAPACITANCE
ANALYZER
Figure 14. COM_, NO_, NC_ Capacitance