Datasheet

Figure 3. Break-Before-Make Interval
Figure 4. Charge Injection
V+
V
OUT
V
OUT
V
ADD
V
ADD
GND
V+
ADDB
ADDA
INH
NO0–N03
COM
V+
MAX4524L
300W
50
35pF
V+
GND
V+
ADD
INH
NO_, NC_
COM
V+
MAX4525L
300W
35pF
50
50%
80%
t
BBM
t
R
< 20ns
t
F
< 20ns
V+
0V
V
COM
V
OUT
V
ADD
0V
0V
V+
V
INH
V
OUT
IS THE MEASURED VOLTAGE DUE TO CHARGE-
TRANSFER ERROR Q WHEN THE CHANNEL TURNS OFF.
V
OUT
Q = V
OUT
x C
L
.
V
OUT
V+
V
OUT
V
NO
= 0V
C
L
= 1000pF
V
INH
GND
V+
ADDA
ADDB
INH
NO_
COM_
MAX4524L
MAX4525L
50
MAX4524L/MAX4525L Low-Voltage, Single-Supply Analog
Multiplexers/Switches
www.maximintegrated.com
Maxim Integrated
8