Datasheet

MAX4511/MAX4512/MAX4513
Quad, Rail-to-Rail, Fault-Protected,
SPST Analog Switches
______________________________________________________________________________________ 13
MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS.
OFF ISOLATION IS MEASURED BETWEEN COM_ AND OFF NO_ OR NC_ TERMINALS.
ON LOSS IS MEASURED BETWEEN COM_ AND ON NO_ OR NC_ TERMINALS.
CROSSTALK IS MEASURED BETWEEN COM_ TERMINALS WITH ALL SWITCHES ON.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED.
V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION.
V+
GND
MEAS. REF.
V+
V-
V-
IN_
COM_
MAX4511
MAX4512
MAX4513
NO_, NC_
ADDRESS SELECT
10nF
10nF
NETWORK
ANALYZER
50
50 50
50
OFF ISOLATION = 20 log
ON LOSS = 20 log
CROSSTALK = 20 log
V
OUT
V
IN
V
OUT
V
IN
V
OUT
V
IN
V
IN
V
OUT
Figure 6. Frequency Response, Off Isolation, and Crosstalk
Test Circuits/Timing Diagrams (continued)
N.C. = NOT CONNECTED
SWITCHES SHOWN FOR LOGIC 0 INPUT.
ALL SWITCHES ARE OFF WITH POWER REMOVED.
DIP/SO
MAX4512
LOGIC SWITCH
0
1
OFF
ON
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
IN2
COM2
NO2
V+
V-
NO1
COM1
IN1
MAX4512
N.C.
NO3
COM3
IN3
IN4
COM4
NO4
GND
TOP VIEW
DIP/SO
MAX4513
LOGIC
SWITCHES
1, 4
0
1
OFF
ON
SWITCHES
2, 3
ON
OFF
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
IN2
COM2
NC2
V+
V-
NO1
COM1
IN1
MAX4513
N.C.
NC3
COM3
IN3
IN4
COM4
NO4
GND
Pin Configurations/Functional Diagrams/Truth Tables (continued)