Datasheet
MAX4510/MAX4520
Rail-to-Rail, Fault-Protected,
SPST Analog Switches
______________________________________________________________________________________ 11
V- IS CONNECTED TO GND FOR SINGLE-SUPPLY OPERATION.
V+
V
IN
GND
V+
V-
V-
IN
NO OR NC
COM
MAX4510
MAX4520
1MHz
CAPACITANCE
ANALYZER
Figure 4. COM, NO, and NC Capacitance
Test Circuits/Timing Diagrams (continued)
MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS.
OFF ISOLATION IS MEASURED BETWEEN COM AND “OFF” NO OR NC TERMINALS.
ON LOSS IS MEASURED BETWEEN COM AND “ON” NO OR NC TERMINALS.
V- IS CONNECTED TO GND FOR SINGLE-SUPPLY OPERATION.
V+
GND
MEAS REF
V+
V-
V-
IN
COM
MAX4510
MAX4520
NO, NC
10nF
10nF
NETWORK
ANALYZER
50Ω
50Ω 50Ω
50Ω
OFF-ISOLATION = 20log
ON-LOSS = 20log
V
OUT
V
IN
V
OUT
V
IN
V
IN
V
OUT
V
IN
Figure 5. Frequency Response and Off-Isolation
TRANSISTOR COUNT: 139
Chip Information