Datasheet

Detailed Description
Rail-to-Rail Output Stage
The MAX4400–MAX4403 can drive a 2k load and still
typically swing within 55mV of the supply rails. Figure 1
shows the output voltage swing of the MAX4400 config-
ured with A
V
= +10V/V.
Driving Capacitive Loads
Driving a capacitive load can cause instability in many op
amps, especially those with low quiescent current. The
MAX4400–MAX4403 are unity-gain stable for a range
of capacitive loads to above 400pF. Figure 2 shows the
response of the MAX4400 with an excessive capacitive
load. Adding a series resistor between the output and the
load capacitor (Figure 3) improves the circuit’s response
by isolating the load capacitance from the op amp’s output.
Figure 1. Rail-to-Rail Output Operation
PIN
NAME FUNCTION
MAX4400 MAX4401 MAX4402 MAX4403
1 1 IN+ Noninverting Amplier Input
3 3 INA+ Noninverting Amplier Input A
5 5 INB+
Noninverting Amplier Input B
10 INC+
Noninverting Amplier Input C
12 IND+ Noninverting Amplier Input D
2 2 4 11
V
SS
Negative Supply. Connect to ground for single- supply
operation.
3 3 IN- Inverting Amplier Input
2 2 INA-
Inverting Amplier Input A
6 6 INB- Inverting Amplier Input B
9 INC- Inverting Amplier Input C
13 IND-
Inverting Amplier Input D
4 4 OUT Amplier Output
1 1 OUTA Amplier Output A
7 7 OUTB
Amplier Output B
8 OUTC Amplier Output C
14 OUTD Amplier Output D
5 6 8 4
V
DD
Positive Supply
5 SHDN
Active-Low Shutdown Input. Connect to
V
DD
for normal
operation. Do not leave unconnected.
1V/div
100µs/div
www.maximintegrated.com
Maxim Integrated
7
MAX4400–MAX4403 Single/Dual/Quad, Low-Cost, Single-Supply,
Rail-to-Rail Op Amps with Shutdown
Pin Description