Datasheet

(V
DD
= 5V, V
SS
= 0V, V
CM
= V
REF
= V
DD
/2, V
REFIN/MODE
= V
SS
, R
L
= 100kΩ to V
DD
/2, V
DIFF
= (V
IN+
- V
IN-
) = 0V, MAX4208 set for
G = 100V/V (R1 = 1kΩ, R2 = 99kΩ), T
A
= +25°C, unless otherwise noted.)
LARGE-SIGNAL PULSE RESPONSE TIME
MAX4208/9 toc17
100µs/div
V
IN+
5mV/div
OUTPUT
50mV/div
2.5V
2.5V
A
V
= 10V/V
V
IN+
= 10mV STEP
V
IN-
= V
REF
= (V
DD
- V
SS
)/2
V
REFIN/MODE
= V
SS
LARGE-SIGNAL PULSE RESPONSE TIME
MAX4208/9 toc18
400µs/div
V
IN+
5mV/div
OUTPUT
500mV/div
2.5V
2.5V
A
V
= 100V/V
V
IN+
= 10mV STEP
V
IN-
= V
REF
= (V
DD
- V
SS
)/2
V
REFIN/MODE
= V
SS
LARGE-SIGNAL PULSE RESPONSE TIME
MAX4208/9 toc19
400µs/div
V
IN+
1mV/div
OUTPUT
1V/div
2.5V
2.5V
A
V
= 1000V/V
V
IN+
= 2mV STEP
V
IN-
= V
REF
= (V
DD
- V
SS
)/2
V
REFIN/MODE
= V
SS
MAX4208/MAX4209 Ultra-Low Offset/Drift, Precision
Instrumentation Ampliers with REF Buffer
Maxim Integrated
9
www.maximintegrated.com
Typical Operating Characteristics (continued)