Datasheet

MAX395
Serially Controlled, Low-Voltage,
8-Channel SPST Switch
10 ______________________________________________________________________________________
0
04
DATA SETUP TIME vs. 
POSITIVE SUPPLY VOLTAGE
20
60
MAX395 TOC10
SUPPLY VOLTAGE (V)
DATA SETUP TIME (ns)
8
40
80
90
100
70
10
50
30
26
100
0.001
-50 125
POWER-SUPPLY CURRENT 
vs. TEMPERATURE
10
1
MAX395 TOC11
TEMPERATURE (°C)
I+, I-, (µA)
25
0.1
0.01
-25 0 7550
100
V± = ±5.5V
I+
I-
10
04
MINIMUM SCLK PULSE WIDTH vs. 
POSITIVE SUPPLY VOLTAGE
15
25
MAX395 TOC12
SUPPLY VOLTAGE (V)
SCLK (ns)
8
20
30
35
26
0
-100
10k 100k 10M 1G
FREQUENCY RESPONSE
-80
-20
MAX395 TOC13
FREQUENCY (Hz)
LOSS (dB)
PHASE (DEGREES)
1M 100M
-40
-60
20
-80
-100
-120
-60
0
-20
-40
PHASE
OFF ISOLATION
INSERTION LOSS
ISOLATION OF
A BARE SOCKET
V± = ±5V
50 IN AND OUT
0.01
10 100 1k 10k
TOTAL HARMONIC DISTORTION
vs. FREQUENCY
0.1
MAX395 TOC14
FREQUENCY (Hz)
TDH (%)
1
10
100
V± = ±5V
600 IN AND OUT
____________________________Typical Operating Characteristics (continued)
(V+ = +5V, V- = -5V, GND = 0V, T
A
= +25°C, unless otherwise noted.)
______________________________________________________________Pin Description
Note: NO_ and COM_ pins are identical and interchangeable. Either may be considered as an input or an output; signals pass
equally well in either direction.
NAME FUNCTION
1 SCLK Serial Clock Digital Input
2 V+ Positive Analog Supply Voltage Input
PIN
3 DIN Serial Data Digital Input
5, 7, 9, 11, 14, 16, 18, 20 NO0–NO7 Normally Open Analog Switches 0–7
6, 8, 10, 12, 13, 15, 17, 19 COM0–COM7 Common Analog Switches 0–7
21 V- Negative Analog Supply Voltage Input. Connect to GND for single-supply operation
22 DOUT Serial Data Digital Output. (High is sourced from V+.)
23 RESET
Reset Input. Connect to digital (logic) supply (or V+). Drive low to set all switch-
es off and set internal shift registers to 0.
24 CS Chip-Select Digital Input (Figure 1)
4 GND
Ground. Connect to digital ground. (Analog signals have no ground reference;
they are limited to V+ and V-.)