Datasheet

Table 14. TOF5 Register
WRITE OPCODE
3Ch
READ OPCODE
BCh
FLASH STORED
Yes
FACTORY-STORED FLASH VALUE
0000h
Bit 15 14 13 12 11 10 9 8
Name X X HIT5WV5 HIT5WV4 HIT5WV3 HIT5WV2 HIT5WV1 HIT5WV0
Bit 7 6 5 4 3 2 1 0
Name X X HIT6WV5 HIT6WV4 HIT6WV3 HIT6WV2 HIT6WV1 HIT6WV0
BIT NAME DESCRIPTION
15:14 X Reserved
13:8 HIT5WV[5:0]
Hit5 Wave Select: These bits select the wave number for which the Hit5 stop time is
measured. Wave numbers are depicted in Figure 5. The Hit5 wave select value must be at
least 1 greater than the Hit4 wave select value. For example, if the Hit4 wave select value is
set to measure wave number 12, then the Hit5 wave select must be set to detect wave number
13 or greater. The earliest wave for which Hit5 can be measured is wave 7.
HIT5WV[5:0] (decimal) DESCRIPTION
0 through 7 Wave 7
8 Wave 8
9 Wave 9
10 through 63 Wave 10 through 63
7:6 X Reserved
5:0 HIT6WV[5:0]
Hit6 Wave Select: These bits select the wave number for which the Hit6 stop time is
measured. Wave numbers are depicted in Figure 5. Hit6 wave select value must at least
1 greater than the Hit5 wave select value. For example, if Hit5 wave select value is set to
measure wave number 13, then the Hit6 wave select must be set to detect wave number 14 or
greater. The earliest wave for which Hit6 can be measured is wave 8.
HIT6WV[5:0] (decimal) DESCRIPTION
0 through 8 Wave 8
9 Wave 9
10 Wave 10
11 through 63 Wave 11 through 63
MAX35101 Time-to-Digital Converter with Analog Front-End
www.maximintegrated.com
Maxim Integrated
42