Datasheet
Register Memory Map
These registers are accessed by the read register com-
mand and the Write Register command: “X” represents a
reserved bit. Following a reset, all configuration variables
are recalled from flash. The factory-stored flash default
value for all configuration registers except TOF1 is 0000h.
The factory-stored flash configuration for TOF1 is 0010h.
After a transfer to configuration to flash command, the
new user configuration data is recalled from flash after
a reset.
The RTC register, Results registers, Interrupt Status, and
Control registers are all 0000h following a reset.
Figure 17. Continuous Write Register Opcode Command Protocol
Figure 17
CE
SCK
DIN
DOUT
O O
OPCODE
D D D
MSB
LSB
8 BITS
D D D D D D
LSBMSB
HIGH IMPEDANCE
CONTINUOUS WRITE REGISTER COMMAND
DATA 16 BITS
0 1 2 3 4 5 109876 20 23222119
25 39272624
D D D D D D D
LSB
MSB
DATA 16 BITS
MAX35101 Time-to-Digital Converter with Analog Front-End
www.maximintegrated.com
Maxim Integrated
│