Datasheet
MAX34451 PMBus 16-Channel V/I Monitor and
12-Channel Sequencer/Marginer
www.maximintegrated.com
Maxim Integrated
│
54
Table 34. MFR_NV_FAULT_LOG (DCh)
ThereisaFAULT_LOG_COUNT (16-bit counter) at the
beginning of each fault log that indicates which fault log
is the latest. This counter rolls over should more than
65,535 faults be logged. This counter is not cleared when
the CLEAR_NV_FAULT_LOG bit in MFR_NV_LOG_
CONFIGistoggled.The255bytesreturnedbytheMFR_
NV_FAULT_LOGcommandaredescribedinTable34.
If an error occurs while the device is attempting to write to
orcleartheMFR_NV_FAULT_LOG,thedevicesetsthe
CMLbitinSTATUS_WORD(nobitsaresetinSTATUS_
CML)andALERTisasserted(ifenabledinMFR_MODE).
USER NOTE:V
DD
mustbeabove2.9Vforthedeviceto
clearorlogdataintoMFR_NV_FAULT_LOG.
BYTE PARAMETER BYTE PARAMETER
0 00h/FAULT_LOG_INDEX 128
READ_VOUT/READ_IOUTT1PAGE11
2 FAULT_LOG_COUNT 130 READ_VOUT/READ_IOUTT2PAGE11
4 MFR_TIME_COUNT(LSW) 132 READ_VOUT/READ_IOUTT0PAGE12
6 MFR_TIME_COUNT(MSW) 134 READ_VOUT/READ_IOUTT1PAGE12
8 0000h 136 READ_VOUT/READ_IOUTT2PAGE12
10 STATUS_CML/00h 138 READ_VOUT/READ_IOUTT0PAGE13
12 STATUS_WORD 140 READ_VOUT/READ_IOUTT1PAGE13
14 STATUS_VOUT/STATUS_IOUTPAGES0/1 142 READ_VOUT/READ_IOUTT2PAGE13
16 STATUS_VOUT/STATUS_IOUTPAGES2/3 144 READ_VOUT/READ_IOUTT0PAGE14
18 STATUS_VOUT/STATUS_IOUTPAGES4/5 146 READ_VOUT/READ_IOUTT1PAGE14
20 STATUS_VOUT/STATUS_IOUTPAGES6/7 148 READ_VOUT/READ_IOUTT2PAGE14
22 STATUS_VOUT/STATUS_IOUTPAGES8/9 150 READ_VOUT/READ_IOUTT0PAGE15
24 STATUS_VOUT/STATUS_IOUTPAGES10/11 152 READ_VOUT/READ_IOUTT1PAGE15
26 STATUS_VOUT/STATUS_IOUTPAGES12/13 154 READ_VOUT/READ_IOUTT2PAGE15
28 STATUS_VOUT/STATUS_IOUTPAGES14/15 156 0000h
30
STATUS_MFR_SPECIFICPAGES0/1 158 0000h
32
STATUS_MFR_SPECIFICPAGES2/3 160 0000h
34
STATUS_MFR_SPECIFICPAGES4/5 162 0000h
36
STATUS_MFR_SPECIFICPAGES6/7 164 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE0
38 STATUS_MFR_SPECIFICPAGES8/9 166 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE1
40 STATUS_MFR_SPECIFICPAGES10/11 168 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE2
42 STATUS_MFR_SPECIFICPAGES12/13 170 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE3
44 STATUS_MFR_SPECIFICPAGES14/15 172 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE4
46 STATUS_MFR_SPECIFICPAGE255/00h 174 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE5
48 STATUS_TEMPERATUREPAGES16/17 176 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE6
50 STATUS_TEMPERATUREPAGES18/19 178 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE7
52 STATUS_TEMPERATUREPAGE20/00h 180 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE8
54 CURRENT_CHANNELS(Note4) 182 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE9
56 0000h 184 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE10
58 0000h 186 MFR_VOUT_PEAK/MFR_IOUT_PEAKPAGE11