Datasheet
MAX34451 PMBus 16-Channel V/I Monitor and
12-Channel Sequencer/Marginer
www.maximintegrated.com
Maxim Integrated
│
29
Table 11. OPERATION (01h) Command Byte with PAGE = 255
(When Bit 3 of ON_OFF_CONFIG = 1)
Table 12. OPERATION (01h) Command Byte (When Bit 3 of ON_OFF_CONFIG = 0)
Note: Special device OPERATION commands are shaded; when the OPERATION command is read, the device always responds
with the standard command; all enabled channels must exceed POWER_GOOD_ON for margining to begin.
Note: The device only takes action if the supply is enabled; all enabled channels must exceed POWER_GOOD_ON for margining to
begin; if PAGE is set to 255, both SEQUENCE0 and SEQUENCE1 are affected.
COMMAND BYTE POWER SUPPLY ON/OFF SEQUENCE AFFECTED MARGIN STATE
00h
Immediate off
(nosequencing)
SEQUENCE0and
SEQUENCE1
n/a
01h
SEQUENCE0only
02h SEQUENCE1only
40h
Soft-off
(withsequencing)
SEQUENCE0and
SEQUENCE1
41h
SEQUENCE0only
42h SEQUENCE1only
80h
On
SEQUENCE0and
SEQUENCE1
Margin off
81h
SEQUENCE0only
82h SEQUENCE1only
94h On
SEQUENCE0and
SEQUENCE1
Marginlow(ignoreallfaults)
98h On Marginlow(actonanyfault)
A4h On Marginhigh(ignoreallfaults)
A8h On Marginhigh(actonanyfault)
COMMAND BYTE
POWER SUPPLY
ON/OFF
MARGIN STATE
00h
Commandhasnoeffect
n/a
40h
80h Margin off
94h
Marginlow(ignoreallfaults)
98h Marginlow(actonanyfault)
A4h Marginhigh(ignoreallfaults)
A8h Marginhigh(actonanyfault)