Multiple Device Connections
Multiple MAX34451 devices can be connected together to
increasethesystemchannelcount.Figure4detailsthe
recommended connection scheme.
All the paralleled devices share the same CONTROLn,
FAULTn, SEQ,andSMBussignals.Thedevicesalluse
acommonsignal(eithertheCONTROL0orCONTROL1
pin,ortheOPERATIONcommand)toenable/disableall
the power supplies. Any of the monitored power supplies
can be configured with the MFR_FAULT_RESPONSE
command to activate one or more of the FAULTn signals
and shut down all the other supplies enabled to respond
to one or more of the FAULTn signals. The FAULT0 signal
is always available, whereas FAULT1 and FAULT2 are
optionalsignals.Whentheyareenabled,thePWM7and
PSEN10outputs(respectively)aredisabled.Theuseof
multiple fault signals allows more flexibility in controlling
which power supplies need to shut down during a fault.
USER NOTE:
●
All devices must be configured with the same ON_
OFF_CONFIGconfiguration.
● All devices must be powered up and reset at the same
time.
Figure 3. Sequencing Example
POWER_GOOD_ON
TON_MAX_FAULT_LIMIT
TON_DELAY
POWER_GOOD_ON
TON_MAX_FAULT_LIMIT
TON_DELAY
POWER_GOOD_ON
TON_MAX_FAULT_LIMIT
TON_DELAY
POWER_GOOD_ON
TON_MAX_FAULT_LIMIT
TOFF_DELAY
TOFF_DELAY
TOFF_DELAY
TOFF_DELAY
NOTES 1 AND 2
TON_DELAY
POWER-DOWNPOWER-UP
CONTROL0/1 PIN
OR OPERATION COMMAND
PSEN0
RS0
RS2
RS5
RS1
SEQ
PSEN2
PSEN5
PSEN1
NOTES: 1. ALTERNATE POWER-DOWN SEQUENCING OPERATION IS TO SHUT OFF ALL SUPPLIES IMMEDIATELY.
2. THE FAULTn PIN BEING ASSERTED LOW CAN ALSO CAUSE A POWER-DOWN SEQUENCE TO OCCUR.