Datasheet

MAX34446
PMBus Power-Supply Data Logger
8Maxim Integrated
Table 1. PMBus Command Codes
CODE COMMAND NAME TYPE
PAGE
0–3
PAGE
4, 5, 6
PAGE
255
NO. OF
BYTES
LOCKED
(NOTE 2)
FLASH
STORED
(NOTE 3)
DEFAULT
VALUE
(NOTE 3)
(NOTE 1)
00h PAGE R/W Byte R/W R/W R/W 1 N N 00h
03h CLEAR_FAULTS Send Byte W W W 0 Y N
10h WRITE_PROTECT R/W Byte R/W R/W R/W 1 Y N 00h
11h STORE_DEFAULT_ALL Send Byte W W W 0 Y N
12h RESTORE_DEFAULT_ALL Send Byte W W W 0 Y N
19h CAPABILITY Read Byte R R R 1 N FIXED 00h
20h VOUT_MODE Read Byte R R R 1 N FIXED 40h
2Ah VOUT_SCALE_MONITOR R/W Word R/W 2 Y Y 7FFFh
38h IOUT_CAL_GAIN R/W Word R/W 2 Y Y 0000h
40h VOUT_OV_FAULT_LIMIT R/W Word R/W 2 Y Y 7FFFh
42h VOUT_OV_WARN_LIMIT R/W Word R/W 2 Y Y 7FFFh
43h VOUT_UV_WARN_LIMIT R/W Word R/W
2 Y Y 0000h
44h VOUT_UV_FAULT_LIMIT R/W Word R/W 2 Y Y 0000h
46h IOUT_OC_WARN_LIMIT R/W Word R/W 2 Y Y 7FFFh
4Ah IOUT_OC_FAULT_LIMIT R/W Word R/W 2 Y Y 0000h
4Fh OT_FAULT_LIMIT R/W Word R/W 2 Y Y 0000h
51h OT_WARN_LIMIT R/W Word R/W 2 Y Y 7FFFh
5Eh POWER_GOOD_ON R/W Word R/W 2 Y Y 0000h
5Fh POWER_GOOD_OFF R/W Word R/W 2 Y Y 0000h
78h STATUS_BYTE Read Byte R R R 1 N N 00h
79h STATUS_WORD Read Word R R R 2 N N 0000h
7Ah STATUS_VOUT Read Byte R 1 N N 00h
7Eh STATUS_CML Read Byte R R R 1 N N 00h
80h STATUS_MFR_SPECIFIC Read Byte R R 1 N N 00h
8Bh READ_VOUT Read Word R 2 N
N 0000h
8Ch READ_IOUT Read Word R 2 N N 0000h
8Dh READ_TEMPERATURE_1 Read Word R 2 N N 0000h
96h READ_POUT Read Word R 2 N N 0000h
98h PMBUS_REVISION Read Byte R R R 1 N FIXED 11h
99h MFR_ID Read Byte R R R 1 N FIXED 4Dh
9Ah MFR_MODEL Read Byte R R R 1 N FIXED 54h
9Bh MFR_REVISION Read Word R R R 2 N FIXED (Note 4)
9Ch MFR_LOCATION Block R/W R/W R/W R/W 8 Y Y (Note 5)
9Dh MFR_DATE Block R/W R/W R/W R/W 8 Y Y (Note 5)
9Eh MFR_SERIAL Block R/W R/W R/W R/W 8 Y Y (Note 5)
D1h MFR_MODE R/W Word R/W R/W R/W 2 Y Y 0000h
D4h MFR_VOUT_PEAK R/W Word R/W 2 Y N 0000h
D5h MFR_IOUT_PEAK R/W Word R/W 2 Y N 0000h
D6h MFR_TEMPERATURE_PEAK
R/W Word R/W 2 Y N 8000h