Datasheet
MAX335
Serial Controlled, 8-Channel SPST Switch
4 _______________________________________________________________________________________
PARAMETER
DOUT Data-Hold Time After Rising
SCLK (Note 4)
SYMBOL MIN TYP MAX
0
UNITS
Data-Setup Time t
DS
ns
200
Rise Time of DOUT (Note 3)
ns
SCLK Low Time
100
t
CL
190 ns
SCLK High Time t
CH
190
ns
ns
CS Lag Time
t
CSH2
240 ns
Data-Hold Time t
DH
0 ns
DOUT Data Valid After
Falling SCLK
t
DO
240
2
ns
µs
Fall Time of DOUT (Note 3) 100 ns
Cycle Time
SCLK Maximum Frequency
2
f
SCLK
2.1
µs
MHz
t
CH +
t
CL
480 ns
CS Lead Time
t
CSS
240 ns
CONDITIONS
C
L
= 10pF
20% V
L
to 70% V
L
, C
L
= 10pF
20% V
L
to 70% V
L
, C
L
= 10pF
70% V
L
to 20% V
L
, C
L
= 10pF
70% V
L
to 20% V
L
, C
L
= 10pF
Note 4: This specification guarantees that data at D
OUT
never appears before SCLK's falling edge.
TIMING CHARACTERISTICS OF SERIAL DIGITAL INTERFACE (Figure 1)
(V
L
= +5V ±10%, V+ = +15V, V- = -15V, T
A
= T
MIN
to T
MAX
, unless otherwise noted.)
400
T
A
= +25°C
Allowable Fall Time at DIN,
SCLK, CS (Note 3)
Allowable Rise Time at DIN,
SCLK, CS (Note 3)
50% of SCLK to 10% of
DOUT CL = 10pF