Datasheet
MAX3353E
USB On-the-Go Charge Pump with Switchable
Pullup/Pulldown Resistors
______________________________________________________________________________________ 15
Table 7. Status Register (13h)
BIT
NUMBER
SYMBOL CONTENTS
0V
BUS_VALID
Device A V
BUS
valid comparator, threshold = 4.55V:
0 = V
BUS
lower than threshold
1 = V
BUS
higher than threshold
1
SESSION_
VALID
Session-valid comparator, threshold = 1.4V:
0 = V
BUS
lower than threshold
1 = V
BUS
higher than threshold
2 SESSION_END
V
BUS
session-end comparator, threshold = 0.5V:
0 = V
BUS
higher than threshold
1 = V
BUS
lower than threshold
3 ID_GND
ID_IN grounded:
0 = not grounded
1 = grounded
4 ID_FLOAT
ID_IN floating:
0 = not floating
1 = floating
5 A_HNP
Set when Device A is configured, BDISC_ACONN is enabled and has attached pullup during HNP;
cleared by resetting BDISC_ACONN bit in control register 1.
6 B_HNP
Set when Device B is configured, BDISC_ACONN is enabled and has asserted an SE0 during HNP;
cleared by resetting BDISC_ACONN bit in control register 1.
7 — Not used
Table 8. Interrupt Register Address Map
POWER-UP REGISTER STATUS
REGISTER ADDRESS
BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0
Interrupt Mask 14h 0 0 0 0 0000
Interrupt Edge 15h 0 0 0 0 0000
Interrupt Latch 16h 0 0 0 0 0000
Table 9. Interrupt Mask Register (14h)
BIT
NUMBER
SYMBOL OPERATION
0V
BUS_VALID_EN
Enables V
BUS_VALID
interrupt
1
SESSION_
VALID_EN
Enables SESSION_VALID
interrupt
2
SESSION_
END_EN
Enables SESSION_END
interrupt
3 ID_GND_EN Enables ID_GND interrupt
4 ID_FLOAT_EN Enables ID_FLOAT interrupt
5 A_HNP_EN Enables A_HNP interrupt
6 — Not used
7 — Not used