Datasheet
ESD Test Conditions
ESD performance depends on a variety of conditions.
Contact Maxim for a reliability report that documents
test setup, test methodology, and test results.
Human Body Model
Figure 5 shows the Human Body Model, and Figure 6
shows the current waveform it generates when dis-
charged into low impedance. This model consists of a
100pF capacitor charged to the ESD voltage of interest,
which is then discharged into the test device through a
1.5kΩ resistor.
MAX3314E
±15kV ESD-Protected, 460kbps, 1µA,
RS-232-Compatible Transceiver
_______________________________________________________________________________________ 5
Table 1. Shutdown Logic Truth Table
SHDN
TRANSMITTER
OUTPUT
RECEIVER
OUTPUT
L High Z Active
H Active Active
Figure 1. Transmitter Outputs When Exiting Shutdown or
Powering Up
1µs/div
SHDN
TOUT
5V/div
0
1.5V/div
0
TIN = GND
TIN = V
CC
Figure 2. Loopback Test Circuit
0.1µF
SHDN
TOUT
RIN
TIN
ROUT
V
CC
GND
5kΩ
+5V
MAX3314E
0.1µF
-5V
1000pF
V-
Figure 3. Loopback Test Result at 120kbps
5µs/div
TOUT
TIN
ROUT
Figure 4. Loopback Test Result at 250kbps
2µs/div
TOUT
TIN
ROUT