Datasheet

6-Channel Intelligent Fan Controller
MAX31785
39
Table 24. MFR_NV_FAULT_LOG (continued)
Note: LOG_VALID is set to DDh if the fault log contains valid data.
BYTE PARAMETER BYTE PARAMETER
84 RESERVED (0000h) 212 MFR_FAN_RUN_TIME Page 2
86 VOLTAGE_INDEX/00h 214 MFR_FAN_RUN_TIME Page 3
88 READ_VOUT Index = 0, Page 17 216 MFR_FAN_RUN_TIME Page 4
90 READ_VOUT Index = 0, Page 18 218 MFR_FAN_RUN_TIME Page 5
92 READ_VOUT Index = 0, Page 19 220 MFR_FAN_PWM_AVG Page 0
94 READ_VOUT Index = 0, Page 20 222 MFR_FAN_PWM_AVG Page 1
96 READ_VOUT Index = 0, Page 21 224 MFR_FAN_PWM_AVG Page 2
98 READ_VOUT Index = 0, Page 22 226 MFR_FAN_PWM_AVG Page 3
100 READ_VOUT Index = 1, Page 17 228 MFR_FAN_PWM_AVG Page 4
102 READ_VOUT Index = 1, Page 18 230 MFR_FAN_PWM_AVG Page 5
104 READ_VOUT Index = 1, Page 19 232 READ_TEMPERATURE_1 Page 6
106 READ_VOUT Index = 1, Page 20 234 READ_TEMPERATURE_1 Page 7
108 READ_VOUT Index = 1, Page 21 236 READ_TEMPERATURE_1 Page 8
110 READ_VOUT Index = 1, Page 22 238 READ_TEMPERATURE_1 Page 9
112 READ_VOUT Index = 2, Page 17 240 READ_TEMPERATURE_1 Page 10
114 READ_VOUT Index = 2, Page 18 242 READ_TEMPERATURE_1 Page 11
116 READ_VOUT Index = 2, Page 19 244 READ_TEMPERATURE_1 Page 12
118 READ_VOUT Index = 2, Page 20 246 READ_TEMPERATURE_1 Page 13
120 READ_VOUT Index = 2, Page 21 248 READ_TEMPERATURE_1 Page 14
122 READ_VOUT Index = 2, Page 22 250 READ_TEMPERATURE_1 Page 15
124 READ_VOUT Index = 3, Page 17 252 READ_TEMPERATURE_1 Page 16
126 READ_VOUT Index = 3, Page 18 254 LOG_VALID (see note)