Datasheet

MAX3172/MAX3174
+3.3V Multiprotocol Software-Selectable
Cable Terminators and Transceivers
_______________________________________________________________________________________ 7
Figure 1. V.11 or V.35 Differential Impedance Measurement
Figure 2. V.35 Common-Mode Impedance Measurement
V
CM
= ±2V
R2
52
R1
52
S1 ON
A
B
S2 ON
OHMMETER
R3
127
Figure 3. V.10/V.28 Driver Test Circuit
C
L
R
L
T
Figure 4. V.10/V.28 Receiver Test Circuit
Test Circuits
V
CM
= ±7V OR ±2V
A
B
S2 OFF
OHMMETER
R2
52
R1
52
S1 ON
R3
127
15pF
TR