Datasheet

MAX3097E/MAX3098E
±15kV ESD-Protected, 32Mbps, 3V/5V,
Triple RS-422/RS-485 Receivers with Fault Detection
8 _______________________________________________________________________________________
Note 1: ALARMD indicates fault for any receiver.
Note 2: Receiver output may oscillate with this differential input condition.
Note 3: See Applications Information for conditions leading to input range fault condition.
X = Dont care
INPUTS OUTPUTS
V
ID
(DIFFERENTIAL
INPUT VOLTAGE)
COMMON-MODE
VOLTAGE
OUT_ ALARM_
ALARMD
t DELAY
(NOTE 1)
FAULT CONDITION
0.475V 1 0 0 Normal Operation
<0.475V and 0.275V 1 Indeterminate Indeterminate Indeterminate
<0.275V and 0.2V 1 1 1 Low Input Differential Voltage
0.2V and -0.2V
Indeterminate
(Note 2)
1 1 Low Input Differential Voltage
-0.2V and >-0.275V 0 1 1 Low Input Differential Voltage
-0.275V and
>-0.475V
0 Indeterminate Indeterminate
-0.475V
13.2V and -10V
000
Indeterminate
X <-10V or >+13.2V
Indeterminate
(Note 3)
11
Outside Common-Mode
Voltage Range
INPUTS OUTPUTS
V
ID
(DIFFERENTIAL
INPUT VOLTAGE)
COMMON-MODE
VOLTAGE
OUT_ ALARM_
ALARMD
t DELAY
(NOTE 1)
FAULT CONDITION
0.2V 1 0 0 Normal Operation
<0.2V and 0.12V
Indeterminate
Indeterminate Indeterminate Indeterminate
<0.12V and - 0.12V
Indeterminate
(Note 2)
1 1 Low Input Differential Voltage
-0.12V and -0.2V
Indeterminate
Indeterminate Indeterminate Indeterminate
-0.2V
13.2V and -
10V
0 0 0 Normal Operation
X
<-10V or
>+13.2V
Indeterminate
(Note 3)
11
Outside Common-Mode Voltage
Range
Table 1. MAX3097E Alarm Function Table (Each Receiver)
Table 2. MAX3098EA Alarm Function Table (Each Receiver)
Note 1: ALARMD indicates fault for any receiver.
Note 2: Receiver output may oscillate with this differential input condition.
Note 3: See Applications Information for conditions leading to input range fault condition.
X = Dont care; for B-grade functionality, replace V
ID
input values in Table 2 with B-grade parameters from Electrical Characteristics.