Datasheet

PIN
MAX3040/MAX3041/
MAX3042B
MAX3043/MAX3044/
MAX3045B
NAME
FUNCTION
1 1 T1IN Transmitter 1 Input
2 2 Y1 Noninverting Transmitter 1 Output
3 3 Z1 Inverting Transmitter 1 Output
4EN
Transmitter Enable High Input. Drive EN high to enable all four
transmitters. When EN is low and EN is high, all transmitters are
disabled and the part enters a low-power shutdown state. The
transmitter outputs are high impedance when disabled.
4 EN12
Transmitter Enable Input to Control Transmitters 1 and 2. Drive EN12
high to enable transmitters 1 and 2. Drive EN12 low to disable
transmitters 1 and 2. The transmitter outputs are high impedance
when disabled. The part enters a low-power shutdown state when
both EN12 and EN34 are low.
5 5 Z2 Inverting Transmitter 2 Output
6 6 Y2 Noninverting Transmitter 2 Output
7 7 T2IN Transmitter 2 Input
8 8 GND Ground
9 9 T3IN Transmitter 3 Input
10 10 Y3 Noninverting Transmitter 3 Output
11 11 Z3 Inverting Transmitter 3 Output
12 EN
Transmitter Enable Low Input. Drive EN low to enable all four
transmitters. When EN is low and EN is high, all transmitters are
disabled and the part enters a low-power shutdown state. The
transmitter outputs are high impedance when disabled.
12 EN34
Transmitter Enable Input to Control Transmitters 3 and 4. Drive EN34
high to enable transmitters 3 and 4. Drive EN34 low to disable
transmitters 3 and 4. The transmitter outputs are high impedance
when disabled. The part enters a low-power shutdown state when
both EN12 and EN34 are low.
13 13 Z4 Inverting Transmitter 4 Output
14 14 Y4 Noninverting Transmitter 4 Output
15 15 T4IN Transmitter 4 Input
16 16 V
CC
Positive Supply. Bypass with a 0.1µF capacitor to GND.