Datasheet
MAX2472/MAX2473
500MHz to 2500MHz
VCO Buffer Amplifiers
_______________________________________________________________________________________ 3
Note 1: Limits are 100% production tested at T
A
= +25°C. Limits over the entire operating temperature range are guaranteed by
design and characterization but are not production tested.
Note 2: This is the recommended operating frequency range. The parts have been characterized over the specified frequency
range and production tested at 900MHz. Operation outside of this range is possible but not guaranteed.
Note 3: Guaranteed by design and characterization.
P
OUT
= -5dBm, f
IN
= 900MHz
f
IN
= 900MHz
f
IN
= 1900MHz
f
IN
= 900MHz
CONDITIONS
dBc-25
dB24Isolation (OUT1 to OUT2)
10.2
9.5
NFNoise Figure
UNITSMIN TYP MAXSYMBOLPARAMETER
Harmonic Suppression
dB
f
IN
= 900MHz, T
A
= +25°C
f
IN
= 600MHz
f
IN
= 1900MHz
f
IN
= 900MHz
P
OUT
= -5dBm, f
IN
= 900MHz
f
IN
= 600MHz
f
IN
= 1900MHz
f
IN
= 2400MHz
f
IN
= 900MHz
f
IN
= 900MHz
f
IN
= 2400MHz
CONDITIONS
Harmonic Suppression
dB
dBc-25
9.2
dB
29
NFNoise Figure
6.8 11.8 16.8
14.8
S
21
2
MHz500 2500f
IN
Input Frequency Range (Note 2)
35
S
12
2
48
50
Reverse Isolation
7.6
7.2
-6.0
P
OUT1dB
Output 1dB Compression Point
UNITSMIN TYP MAXSYMBOLPARAMETER
AC ELECTRICAL CHARACTERISTICS—MAX2473
(
Typical Operating Circuits
, V
CC
= +3V, P
IN
= -25dBm, R
BIAS
= 15kΩ, IN driven from a 50Ω source, OUT LC matched to 50Ω, T
A
=
+25°C, unless otherwise noted.)
dBm
-0.9
R
BIAS
= 23kΩ
R
BIAS
= 11kΩ
f
IN
= 1900MHz 9.9
Transducer Gain dB
f
IN
= 900MHz, T
A
= T
MIN
to T
MAX
(Note 3) 6.4 19.0
S
12
2
f
IN
= 900MHz
f
IN
= 2400MHz
f
IN
= 1900MHz
f
IN
= 600MHz
49
dB
30
34
54
Reverse Isolation
(IN to OUT1)
AC ELECTRICAL CHARACTERISTICS—MAX2472 (continued)
(
Typical Operating Circuits
, V
CC
= +3V, P
IN
= -25dBm, IN driven from a 50Ω source, OUT1 and OUT2 LC matched to 50Ω, T
A
=