Datasheet
MAX192
Low-Power, 8-Channel,
Serial 10-Bit ADC
_______________________________________________________________________________________ 9
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
(MSB) (LSB)
START SEL2 SEL1 SEL0 UNI/BIP SGL/DIF PD1 PD0
Bit Name Description
7(MSB) START The first logic “1” bit after CS goes low defines the beginning of the control byte.
6 SEL2 These three bits select which of the eight channels are used for the conversion.
5 SEL1 See Tables 1 and 2.
4 SEL0
3 UNI/BIP 1 = unipolar, 0 = bipolar. Selects unipolar or bipolar conversion mode. In unipolar
mode, an analog input signal from 0V to VREF can be converted; in differential bipolar
mode, the differential signal can range from -VREF / 2 to +VREF / 2. Select differential
operation if bipolar mode is used.
2 SGL/DIF 1 = single ended, 0 = differential. Selects single-ended or differential conversions. In
single-ended mode, input signal voltages are referred to AGND. In differential mode,
the voltage difference between two channels is measured. Select unipolar operation
if single-ended mode is used. See Tables 1 and 2.
1 PD1 Selects clock and power-down modes.
0(LSB) PD0 PD1
PD0 Mode
0 0 Full power-down (I
Q
= 2µA)
0 1 Fast power-down (I
Q
= 30µA)
1 0 Internal clock mode
1 1 External clock mode
Table 3. Control-Byte Format
Table 2. Channel Selection in Differential Mode (SGL/DIF = 0)
SEL2 SEL1 SEL0 CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7
0 0 0 + –
0 0 1 + –
0 1 0 + –
0 1 1 + –
1 0 0 – +
1 0 1 – +
1 1 0 – +
1 1 1 – +