Datasheet

Positive Linear-Regulator
Output Voltage
The MAX1889 EV kits positive linear-regulator output is
set to 20V by feedback resistors R13 and R14. To gen-
erate output voltages other than 20V (1.25V to 28V),
select different external voltage-divider resistors (R13,
R14). Refer to the Linear-Regulator Controllers, Output
Voltage Selection section in the MAX1889 data sheet
for instructions on selecting the resistors.
Negative Linear-Regulator
Output Voltage
The MAX1889 EV kits negative linear-regulator output
is set to -7V by feedback resistors R10 and R11. To
generate output voltages other than -7V (0 to -22V),
select different external voltage-divider resistors (R10,
R11). Refer to the Linear-Regulator Controllers, Output
Voltage Selection section in the MAX1889 data sheet
for instructions on selecting the resistors.
Evaluates: MAX1889
MAX1889 Evaluation Kit
_______________________________________________________________________________________ 5
SHUNT
LOCATION
THIRD STAGE
POSITIVE CHARGE
PUMP
OPERATING
MODE
1-2 Connected to VBST
One-stage charge
pump powered by
VBST
1-3
(Default)
Connected to
previous stage
charge-pump output
Last stage of a
two-stage or
three-stage
charge pump
1-4 Connected to INPUT
One-stage charge
pump powered by
INPUT
Table 5. JU6 Functions
SHUNT
LOCATION
FIRST STAGE
NEGATIVE CHARGE
PUMP
OPERATING
MODE
1-2 Connected to INPUT
First
stage of a three-
stage charge pump
powered by INPUT
2-3 Connected to PGND
First stage of a three-
stage charge pump
powered by PGND
None Not used
Not used for one-
stage or two-stage
charge pump
Table 6. JU3 Functions
SHUNT
LOCATION
SECOND STAGE
NEGATIVE CHARGE
PUMP
OPERATING
MODE
1-2 Connected to INPUT
First
stage of a two-
stage charge pump
powered by INPUT
1-3
Connected to
previous stage
charge-pump output
Second stage of a three-
stage charge pump
1-4 Connected to PGND
First
stage of a two-
stage charge pump
powered by PGND
None Not used
Not used for one-stage
charge pump
Table 7. JU4 Functions
SHUNT
LOCATION
THIRD STAGE
NEGATIVE CHARGE
PUMP
OPERATING
MODE
1-2 Connected to INPUT
One-stage charge pump
powered by INPUT
1-3
Connected to
previous stage
charge-pump output
Last stage of a two-
stage or three-stage
charge pump
1-4
(Default)
Connected to PGND
One-stage charge pump
powered by PGND
Table 8. JU5 Functions