Datasheet
Low-Power, 8-Channel,
Serial 12-Bit ADCs
Maxim Integrated 7
MAX186/MAX188
+5V
3kΩ
C
LOAD
DGND
DOUT
C
LOAD
DGND
3kΩ
DOUT
a. High-Z to V
OH
and V
OL
to V
OH
b. High-Z to V
OL
and V
OH
to V
OL
+5V
3kΩ
C
LOAD
DGND
DOUT
C
LOAD
DGND
3kΩ
DOUT
a V
OH
to High-Z b V
OL
to High-Z
Figure 1. Load Circuits for Enable Time
Figure 2. Load Circuits for Disabled Time
INPUT
SHIFT
REGISTER
CONTROL
LOGIC
INT
CLOCK
OUTPUT
SHIFT
REGISTER
+2.46V
REFERENCE
(MAX186)
T/H
ANALOG
INPUT
MUX
12-BIT
SAR
ADC
IN
DOUT
SSTRB
V
DD
DGND
V
SS
SCLK
DIN
CH0
CH1
CH3
CH2
CH7
CH6
CH5
CH4
AGND
REFADJ
VREF
OUT
REF
CLOCK
+4.096V
20kΩ
≈ 1.65
1
2
3
4
5
6
7
8
10
11
12
13
15
16
17
18
19
MAX186
MAX188
CS
SHDN
A
20
14
9
Figure 3. Block Diagram
________________________________________________Pin Description (continued)
PIN NAME FUNCTION
12 REFADJ
Input to the Reference-Buffer Amplifier. To disable the reference-buffer amplifier, connect REFADJ to
V
DD
.
13 AGND Analog Ground. Also IN- Input for single-ended conversions.
14 DGND Digital Ground
15 DOUT Serial Data Output. Data is clocked out at the falling edge of SCLK. High impedance when CS is high.
16 SSTRB
Serial Strobe Output. In internal clock mode, SSTRB goes low when the MAX186/MAX188 begin the
A/D conversion and goes high when the conversion is done. In external clock mode, SSTRB pulses
high for one clock period before the MSB decision. High impedance when CS is high (external mode).
17 DIN Serial Data Input. Data is clocked in at the rising edge of SCLK.
18 CS
Active-Low Chip Select. Data will not be clocked into DIN unless CS is low. When CS is high, DOUT
is high impedance.
19 SCLK
Serial Clock Input. Clocks data in and out of serial interface. In external clock mode, SCLK also sets
the conversion speed. (Duty cycle must be 40% to 60% in external clock mode.)
20 V