MAX1823/MAX1823A/MAX1823B/MAX1823H
Dual USB Switch with Fault
Blanking and Autoreset
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
IN, INA, INB, ONA, ONB, ONA, ONB
OUTA, OUTB to GND ...........................................-0.3V to +6V
FAULTA, FAULTB to GND..........................-0.3V to (V
IN_
+ 0.3V)
MAX1823/MAX1823H, INA, IN to OUTA;
INB, IN to OUTB ...................................................-0.3V to +6V
MAX1823A/MAX1823B, INA, IN to OUTA;
INB, IN to OUTB (when disabled, Note 3)...............-6V to +6V
INA, IN to OUTA; INB, IN to OUTB
(when enabled, Note 4)..............................-1.5A to +1.5A
RMS
FAULTA, FAULTB Current .................................................20mA
Continuous Power Dissipation (T
A
= +70°C)
10-Pin µMAX (derate 5.6mW/°C above +70°C) ...........444mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage Range 4.0 5.5 V
T
A
= +25°C, each switch,
MAX1823/MAX1823H
75 105
T
A
= +25°C, each switch,
MAX1823A/MAX1823B
90 120
T
A
= 0°C to +85°C, each switch,
MAX1823/MAX1823H
135
Switch On-Resistance R
ON
T
A
= 0°C to +85°C, each switch,
MAX1823A/MAX1823B
165
mΩ
Standby Supply Current
ON_ = IN_ (MAX1823/MAX1823A), ON_ =
GND (MAX1823B/MAX1823H)
310µA
I
OUTA
= I
OUTB
= 0A, one channel on 40 80
Quiescent Supply Current
I
OUTA
= I
OUTB
= 0A, both channels on 50 100
µA
ON_ = IN _ ( MAX 1823/M AX1823A), ON _ = GND
(M AX1823B/M AX1823H), V
OUTA
= V
OUTB
= 0V,
T
A
= +25
o
C
0.02 1.00
OUT_ Off-Leakage Current
ON_ = IN_ (MAX1823/MAX1823A), ON_ =
GND (MAX1823B/MAX1823H),
V
OUTA
= V
OUTB
= 0V, T
A
= 0
o
C to +85
o
C
0.02 10.00
µA
Undervoltage-Lockout Threshold V
UVLO
Rising edge, 3% hysteresis 3.0 3.4 3.8 V
Continuous Load Current 720 mA
Continuous Current Limit I
LIM
V
IN
- V
OUT_
= 0.5V 0.72 0.90 1.20 A
V
OUT_
= 0V (I
OUT
pulsing) 0.8 1.2 1.6 A
PEAK
Short-Circuit Current Limit I
SHORT
V
OUT_
= 0V (I
OUT
pulsing) 0.35 A
RMS
ELECTRICAL CHARACTERISTICS
(Circuit of Figure 1, V
IN
= V
INA
= V
INB
= 5V, ONA = ONB = GND (MAX1823/MAX1823A), ONA = ONB = IN (MAX1823B/MAX1823H),
T
A
= 0°C to +85°C, unless otherwise noted. Typical values are at T
A