Datasheet

MAX1778/MAX1880–MAX1885
Quad-Output TFT LCD DC/DC
Converters with Buffer
18
Maxim Integrated
Pin Description (continued)
PIN
MAX1778
MAX1881
MAX1880
MAX1882
MAX1883
MAX1884
MAX1885
NAME FUNCTION
14 12 LDOOUT
Linear Regulator Output. Sources up to 40mA. Bypass to GND with
a ceramic capacitor determined by:
15 13 FBL
Voltage Setting Input. Connect a resistive divider from the linear
regulator output (V
LDOOUT
) to FBL to analog ground (GND).
16 16 14 14 FLTSET
Fault Trip-Level Set Input. Connect to a resistive divider between
REF and GND to set the main step-up converter’s and positive
charge pump’s fault thresholds between 0.67 x V
REF
and 0.85 x
V
REF
. Connect to GND for the preset fault threshold (0.9 x V
REF
).
17 17 SUPN
Negative Charge-Pump Driver Supply Voltage. Bypass to power
ground (PGND) with a 0.1µF capacitor.
18 18 DRVN
Negative Charge-Pump Driver Output. Output high level is V
SUPN
and low level is PGND.
19 19 SUPP
Positive Charge-Pump Driver Supply Voltage. Bypass to power
ground (PGND) with a 0.1µF capacitor.
20 20 DRVP
Positive Charge-Pump Driver Output. Output high level is V
SUPP
and low level is PGND
21 21 17 17 PGND
Power Ground. Connect to analog ground (GND) underneath the
IC.
22 22 18 18 LX
Main Step-Up Regulator Power MOSFET N-Channel Drain. Place
output diode and output capacitor as close as possible to PGND.
23 23 19 19 TGND Must be connected to ground.
24 24 20 20 RDY
Active-Low, Open-Drain Output. Indicates all outputs are ready.
On-resistance is 125 (typ).
13–15 15, 16
11–13,
15, 16
N.C. No Connection. Not internally connected.
CmsX
I
V
LDOOUT
LDOOUT MAX
LDOOUT
.
()
05