Datasheet
MaximIntegrated
│
3
Evaluates: MAX17504 in
3.3V Output-Voltage Application
MAX17504 3.3V Output Evaluation Kit
www.maximintegrated.com
Regulator Enable/Undervoltage-Lockout
Level (EN/UVLO)
The device offers an adjustable input undervoltage-
lockout level. For normal operation, a shunt should be
installedacrosspins1-2onjumperJU1.Todisablethe
output,installashuntacrosspins2-3onJU1andtheEN/
UVLOpinispulledtoGND.SeeTable 1forJU1settings.
Setthevoltageatwhichthedeviceturnsonwiththeresis-
tivevoltage-dividerR1/R2connectedfromVIN_toSGND.
ConnectthecenternodeofthedividertoEN/UVLO.
ChooseR1tobe3.32MΩandthencalculateR2asfollows:
INU
R1 1.215
R2
(V 1.215)
×
=
−
where V
INU
is the voltage at which the device is required
to turn on.
MODE Selection (MODE)
The device’s MODE pin can be used to select among
PWM,PFM,orDCMmodesofoperation.Thelogicstate
oftheMODEpinislatchedwhenVCCandEN/UVLOvolt-
agesexceedtherespectiveUVLOrisingthresholdsand
allinternalvoltagesarereadytoallowLXswitching.State
changes on the MODE pin are ignored during normal
operation.RefertotheMAX17504ICdatasheetformore
informationonPWM,PFM,andDCMmodesofoperation.
Table 2 shows EV kit jumper settings that can be used to
configure the desired mode of operation.
External Clock Synchronization (SYNC)
The internal oscillator of the device can be synchronized
toanexternalclocksignalontheSYNCpin.Theexternal
synchronization clock frequency must be between 1.1f
SW
and 1.4f
SW
, where f
SW
is the frequency of operation
setbyR5.Theminimumexternalclockhighpulsewidth
should be greater than 50ns and the minimum external
clocklowpulsewidthshouldbegreaterthan160ns.
*Default position.
*Default position.
*Default position.
SHUNT
POSITION
SYNC PIN MAX17504_ SYNC
1-2
Connected to
testlooponPCB
Frequencycanbe
synchronized with an
external clock
2-3*
Connected to
SGND
SYNCfeatureunused
SHUNT
POSITION
EN/UVLO PIN MAX17504_ OUTPUT
1-2* ConnectedtoVIN Enabled
Not
installed
Connected to the
center node of
resistor-dividerR1
andR2
Enabled,UVLOlevel
setthroughtheR1and
R2resistors
2-3 ConnectedtoSGND Disabled
SHUNT
POSITION
MODE PIN MAX17504_ MODE
Not installed* Unconnected
PFMmodeof
operation
1-2
Connected to
SGND
PWMmodeof
operation
2-3
Connected to
VCC
DCM mode of
operation
Table 1. Regulator Enable (EN/UVLO)
Description (JU1)
Table 2. MODE Description (JU2)
Table 3. SYNC Description (JU3)