Datasheet
45Maxim Integrated
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16070/MAX16071
Register Map (continued)
FLASH
ADDRESS
REGISTER
ADDRESS
READ/
WRITE
DESCRIPTION
GPIO AND OUTPUT DEPENDENCIES/CONFIGURATIONS
230 030 R/W Reserved
231 031 R/W Reserved
232 032 R/W Reserved
233 033 R/W Reserved
234 034 R/W Reserved
235 035 R/W SMBALERT pin configuration
236 036 R/W Fault1 dependencies
237 037 R/W Fault1 dependencies
238 038 R/W Fault2 dependencies
239 039 R/W Fault2 dependencies
23A 03A R/W Fault1/Fault2 secondary overcurrent dependencies
23B 03B R/W RESET output configuration
23C 03C R/W RESET output dependencies
23D 03D R/W RESET output dependencies
23E 03E R/W GPIO data out
23F 03F R/W GPIO configuration
240 040 R/W GPIO configuration
241 041 R/W GPIO configuration
242 042 R/W GPIO push-pull/open drain
ADC—CONVERSIONS
243 043 R/W ADCs voltage ranges—MON_ monitoring
244 044 R/W ADCs voltage ranges—MON_ monitoring
245 045 R/W ADCs voltage ranges—MON_ monitoring
246 046 R/W Differential pairs enables
247 047 R/W Current-sense gain-setting (CSP, HV or LV)
INPUT THRESHOLDS
248 048 R/W MON1 secondary selectable UV/OV
249 049 R/W MON1 primary OV
24A 04A R/W MON1 primary UV
24B 04B R/W MON2 secondary selectable UV/OV
24C 04C R/W MON2 primary OV
24D 04D R/W MON2 primary UV
24E 04E R/W MON3 secondary selectable UV/OV
24F 04F R/W MON3 primary OV
250 050 R/W MON3 primary UV
251 051 R/W MON4 secondary selectable UV/OV
252 052 R/W MON4 primary OV
253 053 R/W MON4 primary UV