Datasheet
44 Maxim Integrated
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16070/MAX16071
Register Map
FLASH
ADDRESS
REGISTER
ADDRESS
READ/
WRITE
DESCRIPTION
ADC VALUES, FAULT REGISTERS, GPIO_S AS INPUT PORTS–NOT IN FLASH
— 000 R MON1 ADC output, MSBs
— 001 R MON1 ADC output, LSBs
— 002 R MON2 ADC output, MSBs
— 003 R MON2 ADC output, LSBs
— 004 R MON3 ADC output, MSBs
— 005 R MON3 ADC output, LSBs
— 006 R MON4 ADC output, MSBs
— 007 R MON4 ADC output, LSBs
— 008 R MON5 ADC output, MSBs
— 009 R MON5 ADC output, LSBs
— 00A R MON6 ADC output, MSBs
— 00B R MON6 ADC output, LSBs
— 00C R MON7 ADC output, MSBs
— 00D R MON7 ADC output, LSBs
— 00E R MON8 ADC output, MSBs
— 00F R MON8 ADC output, LSBs
— 010 R MON9 ADC output, MSBs
— 011 R MON9 ADC output, LSBs
— 012 R MON10 ADC output, MSBs
— 013 R MON10 ADC output, LSBs
— 014 R MON11 ADC output, MSBs
— 015 R MON11 ADC output, LSBs
— 016 R MON12 ADC output, MSBs
— 017 R MON12 ADC output, LSBs
— 018 R Current-sense ADC output
— 019 R CSP ADC output, MSBs
— 01A R CSP ADC output, LSBs
— 01B R/W Fault register--failed line flags
— 01C R/W Fault register—failed line flags/overcurrent
— 01D R Reserved
— 01E R GPIO data in (read only)
— 01F R Reserved
— 020 R/W Flash status/reset output monitor
— 021 R Reserved