Datasheet

44 Maxim Integrated
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16070/MAX16071
Register Map
FLASH
ADDRESS
REGISTER
ADDRESS
READ/
WRITE
DESCRIPTION
ADC VALUES, FAULT REGISTERS, GPIO_S AS INPUT PORTS–NOT IN FLASH
000 R MON1 ADC output, MSBs
001 R MON1 ADC output, LSBs
002 R MON2 ADC output, MSBs
003 R MON2 ADC output, LSBs
004 R MON3 ADC output, MSBs
005 R MON3 ADC output, LSBs
006 R MON4 ADC output, MSBs
007 R MON4 ADC output, LSBs
008 R MON5 ADC output, MSBs
009 R MON5 ADC output, LSBs
00A R MON6 ADC output, MSBs
00B R MON6 ADC output, LSBs
00C R MON7 ADC output, MSBs
00D R MON7 ADC output, LSBs
00E R MON8 ADC output, MSBs
00F R MON8 ADC output, LSBs
010 R MON9 ADC output, MSBs
011 R MON9 ADC output, LSBs
012 R MON10 ADC output, MSBs
013 R MON10 ADC output, LSBs
014 R MON11 ADC output, MSBs
015 R MON11 ADC output, LSBs
016 R MON12 ADC output, MSBs
017 R MON12 ADC output, LSBs
018 R Current-sense ADC output
019 R CSP ADC output, MSBs
01A R CSP ADC output, LSBs
01B R/W Fault register--failed line flags
01C R/W Fault register—failed line flags/overcurrent
01D R Reserved
01E R GPIO data in (read only)
01F R Reserved
020 R/W Flash status/reset output monitor
021 R Reserved