Instruction Manual
MAX15303 PMBus Command Set User’s Guide 
Page 46 of 52 
STRAP_DISABLE 
16  VOUT_TRIM 
No function; intended to support a possible pin-strap voltage 
trimming scheme that was never implemented. 
15  INTERLEAVE 
Command set indirectly by the SMBus slave address, from 
R
ADDR0
 and R
ADDR1
 resistor values. 
14  COMP_MODEL 
The F
LC
 data is set automatically by the parametric extraction 
process 
13 
VOUT_MAX 
Command set indirectly according to VOUT_COMMAND x 110% 
12 
IOUT_CAL_GAIN 
Command set by R
ADDR1
 resistor value 
11 
FREQUENCY_SWITCH 
Command set by R
SYNC
 resistor value 
10 
<RESERVED> 
9 
IOUT_OC_FAULT_LIMIT 
Command not set automatically; flag is for future sue 
8 
VOUT_MARGIN_LOW 
Command set indirectly according to VOUT_COMMAND x 95% 
7 
VOUT_MARGIN_HIGH 
Command set indirectly according to VOUT_COMMAND x 105% 
6 
POWER_GOOD_OFF 
Command set indirectly according to VOUT_COMMAND x 85% 
5 
POWER_GOOD_ON 
Command set indirectly according to VOUT_COMMAND x 90% 
4 
VOUT_UV_WARN_LIMIT 
Undervoltage warning is not implemented 
3 
VOUT_UV_FAULT_LIMIT 
Command set indirectly according to VOUT_COMMAND x 85% 
2 
VOUT_OV_WARN_LIMIT 
Overvoltage warning is not implemented 
1 
VOUT_OV_FAULT_LIMIT 
Command set indirectly according to VOUT_COMMAND x 115% 
0 
VOUT_COMMAND 
Command set by R
SET
 resistor value 