Instruction Manual
MAX15303 PMBus Command Set User’s Guide 
Page 30 of 52 
READ_TEMPERATURE_1 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x8D 
Format: 
Linear 
Data Bytes: 
2 
Units: 
°C 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.6 of the PMBus Specification Part II. 
The MAX15303 uses READ_TEMPERATURE_1 to report its internal (i.e., die) temperature. 
READ_TEMPERATURE_2 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x8E 
Format: 
Linear 
Data Bytes: 
2 
Units: 
°C 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.6 of the PMBus Specification Part II. 
The MAX15303 uses READ_TEMPERATURE_2 to report external temperature as measured by an 
external diode junction, typically placed near the power inductor  to facilitate READ_IOUT
temperature compensation. 
If no external diode junction is detected, READ_TEMPERATURE_2 returns a value of -273°C and is not 
used for temperature faults or READ_IOUT temperature compensation. 
The Maxim-specific command EXT_TEMP_CAL
 can be used to adjust the diode ideality factor to 
match that of the actual diode junction used for external temperature sensing and to add or remove 
a fixed temperature offset for calibration purposes. 
READ_DUTY_CYCLE 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x94 
Format: 
Linear 
Data Bytes: 
2 
Units: 
% 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.9 of the PMBus Specification Part II. 
The READ_DUTY_CYCLE command returns an averaged measure of the pulse-width modulator output 
value in percent. The duty-cycle value is averaged over 256 PWM cycles. 
READ_FREQUENCY 
Reference: 
Standard Command 
Lockable: 
N/A 
Command Code: 
0x95 
Format: 
Linear 
Data Bytes: 
2 
Units: 
kHz 
Transfer: 
Read Word 
Factory Value: 
N/A 
Description/Notes: 
See Section 18.10 of the PMBus Specification Part II. 