VOUT_UV_FAULT_RESPONSE 
The VOUT_UV_FAULT_RESPONSE command data comprises three bit-fields: 
Bits [7:6] determine the basic fault-response mode. The MAX15303 supports the following modes: 
00  Ignore the fault condition. (Default setting) 
01  Continue operating and wait for the fault to abate for time specified in bits [2:0]. If the 
  fault does not abate, shutdown and attempt to restart according to bits [5:3]. 
10  Stop regulating immediately, delay for the time specified in bits [2:0], then attempt to 
  restart according to bits [5:3]. 
11  Stop regulating immediately, and then restart as soon as possible after the fault 
  condition abates. 
Bits [5:3] determine the number of retry attempts. The MAX15303 supports only a subset of the full 
PMBus functionality for this portion of the command: 
000-110  No attempt is made to restart after a fault shutdown. (Default setting) 
111  Attempt to restart continuously until commanded off, or until another fault 
  condition causes the unit to shut down. 
Bits [2:0] determine the fault-tolerance or retry-delay timing. Each binary value in bits [2:0] 
corresponds to a multiple of 100ms, up to a possible maximum of 111
bin
 = 700ms. A value of 000
bin
will cause the MAX15303 to use the minimum possible timing value, typically about 30-40ms. (The 
default timing for undervoltage faults is 000
bin
.) 
IOUT_OC_FAULT_LIMIT 
Reference:  Standard Command  Lockable:  Yes 
Command Code:  0x46  Format:  Linear 
Data Bytes:  2  Units:  A 
Transfer:  Read/Write Word  Factory Value:  0xD200 (8A) 
Description/Notes:  See Section 15.8 of the PMBus Specification Part II. 
The MAX15303 hardware has 8-bit resolution for the overcurrent fault limit within a 9A full-scale load 
current range. 
The desired value of IOUT_OC_FAULT_LIMIT is retained in memory, regardless limitations imposed by 
the 8-bit fault limit resolution, but the read-back value is based on actual hardware register settings. 
IOUT_OC_FAULT_RESPONSE 
Reference:  Standard Command  Lockable:  Yes 
Command Code:  0x47  Format:  Bit field 
Data Bytes:  1  Units:  N/A 
Transfer:  Read/Write Byte  Factory Value:  0xBF (Shut down, retry every 700ms) 
Description/Notes:  See Sections 10.5.1 and 15.9 of the PMBus Specification Part II. 
For overcurrent faults, the MAX15303 implements the fault responses of PMBus Specification section 
10.5.1, rather than the responses of section 10.5.2. 
Note that… 