VIN_OFF 
Reference: 
Standard Command 
Lockable: 
Yes 
Command Code: 
0x36 
Format: 
Linear 
Data Bytes: 
2 
Units: 
V 
Transfer: 
Read/Write Word 
Factory Value: 
0xCAC0 (5.5V) 
Description/Notes: 
See Section 14.6 of the PMBus Specification Part II. 
The MAX15301 hardware has 8-bit resolution for the minimum input voltage required for regulation, 
to a maximum value of ≈14.75V. 
The desired value of VIN_OFF is retained in memory, regardless limitations imposed by the 8-bit fault 
limit resolution, but the read-back value is based on actual hardware register settings. 